Installation

Installation Requirements

Important:

Installation shall comply with local electrical, health and safety requirements.

It is most important that this proofer / holding cabinet is installed correctly and that the operation is correct before use.

If you have any questions regarding the proper installation and / or operation of this proofer / holding cabinet , please contact your local Turbofan distributor.

Unpacking

1.Remove all packaging and transit protection including all protective plastic coating from the exterior stainless steel panels.

2.Check the proofer / holding cabinet and supplied parts for damage. Report any damage immediately to the carrier and distributor.

3.Check that the following parts have been supplied with your proofer / holding cabinet:-

Water Inlet Elbow c/w Rubber Washer.

4.Report any deficiencies to the distributor who supplied the appliance.

5.Ensure that all the castors are fitted securely.

6.Check that the available electrical supply is correct to as shown on the Technical Data Plate located on the front right hand side panel.

-Refer to ‘Specifications’ section, ‘P8M / P12M Specifications Tables’.

Location

1.Position the proofer / holding cabinet in its working position.

2.The proofer / holding cabinet should be positioned so that the control panel and shelves are easily reachable for loading and unloading.

Proofer / Holding Cabinet

Serial Number

Electrical Power

 

 

 

 

 

 

 

 

 

 

Proofer / Holding Cabinet

Rating

 

 

 

 

 

 

Model Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current Draw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOFFAT LIMITED

 

 

 

 

 

 

 

MODEL

 

P8M

 

 

 

CHRISTCHURCH ( NEW ZEALAND )

 

 

 

 

 

 

 

 

CODE

 

USP8M

 

 

 

 

 

 

SERIAL

 

xxxxxx

 

 

 

 

 

 

 

LOT

 

*******

 

 

 

 

11.6 A @ 115 V a.c.

 

 

 

 

 

 

 

 

 

 

1P+N+E 110-120V a.c. 50-60Hz 1.45 kW

THIS APPLIANCE MUST BE EARTHED / GROUNDED

THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE WITH CURRENT

REGULATIONS AND USED ONLY IN A WELL-VENTILATED SPACE. REFER TO THE

INSTRUCTIONS BEFORE INSTALLING AND USING THIS APPLIANCE.

Technical Data Plate - Data and Location

(example only)

Clearances

To ensure correct ventilation for the motor and controls, the following minimum installation clearances are to be adhered to:-

Top

0 mm / 0”.

Rear

0 mm / 0”.

Left-hand side

0 mm / 0”.

Right-hand side

25 mm / 1”.

Electrical Connection

Warning

This proofer / holding cabinet must be earthed/grounded.

If the supply cord is damaged, it must be replaced by a suitably qualified person in order to avoid a hazard.

Each proofer / holding cabinet should be connected to an adequately protected power supply and an isolation switch mounted adjacent to, but not behind the proofer / holding cabinet and must be readily accessible to the operator. This switch must be clearly marked and readily accessible in case of fire.

Check that the electricity supply is correct to as shown on the Technical Data Plate on the front right hand corner of the proofer / holding cabinet side panel.

The P8 / P12 Proofer / Holding Cabinets are supplied with electrical cords fitted . Ensure that the appliance is fitted with the appropriate power cord and plug.

4

Page 6
Image 6
Moffat P8M, P12M operation manual Installation Requirements, Unpacking, Clearances, Electrical Connection