Installation
Installation Requirements
Important:
•Installation shall comply with local electrical, health and safety requirements.
•It is most important that this proofer / holding cabinet is installed correctly and that the operation is correct before use.
•If you have any questions regarding the proper installation and / or operation of this proofer / holding cabinet , please contact your local Turbofan distributor.
Unpacking
1.Remove all packaging and transit protection including all protective plastic coating from the exterior stainless steel panels.
2.Check the proofer / holding cabinet and supplied parts for damage. Report any damage immediately to the carrier and distributor.
3.Check that the following parts have been supplied with your proofer / holding cabinet:-
Water Inlet Elbow c/w Rubber Washer.
4.Report any deficiencies to the distributor who supplied the appliance.
5.Ensure that all the castors are fitted securely.
6.Check that the available electrical supply is correct to as shown on the Technical Data Plate located on the front right hand side panel.
-Refer to ‘Specifications’ section, ‘P8M / P12M Specifications Tables’.
Location
1.Position the proofer / holding cabinet in its working position.
2.The proofer / holding cabinet should be positioned so that the control panel and shelves are easily reachable for loading and unloading.
Proofer / Holding Cabinet
Serial Number
Electrical Power |
|
|
|
|
|
|
| |||
|
|
| Proofer / Holding Cabinet | |||||||
Rating |
|
|
| |||||||
|
|
| Model Number | |||||||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| |
|
| Current Draw |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| MOFFAT LIMITED |
|
|
|
|
|
| ||
| MODEL |
| P8M |
| ||||||
|
| CHRISTCHURCH ( NEW ZEALAND ) |
|
| ||||||
|
|
|
|
|
| CODE |
| USP8M |
| |
|
|
|
|
| SERIAL |
| xxxxxx |
| ||
|
|
|
|
|
| LOT |
| ******* |
|
|
|
| 11.6 A @ 115 V a.c. |
|
| ||||||
|
|
|
|
|
|
|
|
1P+N+E 110-120 V a.c. 50-60 Hz 1.45 kW
THIS APPLIANCE MUST BE EARTHED / GROUNDED
THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE WITH CURRENT
REGULATIONS AND USED ONLY IN A
INSTRUCTIONS BEFORE INSTALLING AND USING THIS APPLIANCE.
Technical Data Plate - Data and Location
(example only)
Clearances
To ensure correct ventilation for the motor and controls, the following minimum installation clearances are to be adhered to:-
Top | 0 mm / 0”. |
Rear | 0 mm / 0”. |
0 mm / 0”. | |
25 mm / 1”. |
Electrical Connection
Warning
This proofer / holding cabinet must be earthed/grounded.
If the supply cord is damaged, it must be replaced by a suitably qualified person in order to avoid a hazard.
Each proofer / holding cabinet should be connected to an adequately protected power supply and an isolation switch mounted adjacent to, but not behind the proofer / holding cabinet and must be readily accessible to the operator. This switch must be clearly marked and readily accessible in case of fire.
Check that the electricity supply is correct to as shown on the Technical Data Plate on the front right hand corner of the proofer / holding cabinet side panel.
The P8 / P12 Proofer / Holding Cabinets are supplied with electrical cords fitted . Ensure that the appliance is fitted with the appropriate power cord and plug.