Monessen Hearth EYF18 Clearances And Height Requirements, Minimum Mantel Clearance with Hood

Models: EYF24 EYF18

1 36
Download 36 pages 14.74 Kb
Page 13
Image 13
Figure 7 - Minimum Mantel Clearance

CLEARANCES AND HEIGHT REQUIREMENTS

HEAT RESISTANT MATERIAL

MEASUREMENT

REQUIREMENTS FOR SAFE INSTALLATION WITH WOODEN MANTEL, SHELF

OR OTHER COMBUSTIBLE PROJECTION

20" or more

 

Hood not required. Observe profiles (side elevations) shown in Figure 8.

 

 

 

8" to less than 20"

 

Install hood (CABR/CABL) and observe profiles shown in Figure 7; OR extend heat

 

 

resistant material to at least 12" and observe profiles shown in Figure 8.

Less than 8"

 

Extend heat resistant material to at least 8", install hood (CABR/CABL) and observe

 

 

profiles shown in Figure 7; OR extend heat resistant material to at least 12" and observe

 

 

profiles shown in Figure 8.

 

TABLE B - Heat Resistant Material Heights and Mantel Location

12"

 

 

6" - 10 "

 

 

21/2"

 

 

Heat

 

 

Resistant

 

 

Material

 

 

8"min. 13"

18"

20"

Hood

 

 

Heater in Fireplace or Firebox

 

 

Figure 7 - Minimum Mantel Clearance

with Hood

Example: A mantel may project from the wall a maxi- mum of 2 1/2" at a minimum of 13" above the opening and a maximum of 10" at a minimum of 18" above the opening.

10" or less

Heat

Resistant

Material

20" min. 32"

Heater in

Fireplace or

Firebox

Figure 8 - Minimum Mantel Clearance

with No Hood

Example: The bottom of the mantel may project from the wall a maximum of 10" at a minimum of 32" above the opening.

65D1009

13

Page 13
Image 13
Monessen Hearth EYF18, EYF24 operating instructions Clearances And Height Requirements, Minimum Mantel Clearance with Hood