MANUAL CONTROL LIGHTING INSTRUCTIONS

1.STOP! Read the safety information.

2.Make sure the manual shutoff valve is fully open.

3.This heater is equipped with an ignition device (piezo) which automatically lights the pilot.

4.See Figure 35, page 26 for the location of the piezo ignitor and control knob. Push in gas control knob slightly

and turn control knob clockwise

to the OFF position.

NOTE: Knob cannot be turned to OFF unless knob is pushed in slightly. Do not force.

5.Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP! Fol- low the instructions under What to Do if You Smell Gas, page 26. If you do not smell gas, go to the next step.

6.From OFF position, push in gas control knob slightly and turn counterclockwise TO TURN OFF HEATER to the IGN posi- tion. Figure 36. Push in and hold control knob for 5 seconds.

NOTE: If you are running the heater for the first time, it will be necessary to press in the control knob for 30 seconds to allow air to bleed out of the gas piping.

7.With the control knob pushed in, push and release the piezo ignitor button to light the ODS pilot. The pilot is located behind the front log and front burner. If piezo ignitor does not light the pilot, see Match Lighting Instructions, page 29.

8.Hold the control knob in for an additional 10 seconds to prevent the ODS pilot from shutting off the gas while the thermocouple is warming up.

9.Release the control knob.

If the knob does not pop out when released, stop and immediately call your service technician or gas sup- plier.

If the ODS pilot will not stay lit after several tries, push and turn the gas control knob clockwiseManual background to OFF and wait 15 seconds. Repeat steps 6 through 9.

10.Push in control knob and turn counterclockwise Manual backgroundto the HIGH setting. At this location the control knob will pop out when positioned correctly. The knob can now be positioned at any position between HIGH and LOW. See Figures 37 and 38.

Rotate

Rotate

Rotate

HI

HI

HI

 

Push

Push

 

 

 

LO

LO

LO

Figure 36 - IGN Position

Figure 37 - HIGH Position

Figure 38 - LOW Position

WARNING

WARNING

Wait 30 seconds before readjusting the heater when the control knob has been turned down to a lower setting.

TO TURN OFF HEATER

1.Turn control knob clockwiseManual background to OFF position to completely shut off the heater.

2.If applicable: Turn off all electric power to the heater.

65D1009