ELECTRICAL WIRING (MILLIVOLT)
CONNECTING OPTIONAL REMOTE RECEIVER
FOLLOW INSTRUCTIONS SUPPLIED WITH THE REMOTE.
1.Connect the wires to the two .25" male connectors located on the left side of the valve when facing the unit (See Figure 16, page 19). Do not let wire touch grate or burner.
2.Stick velcro pads with
3.Attach remote receiver with velcro pads. Control switch must face forward.
NOTE: Heat reduces battery life. You can protect the receiver and extend battery life by mounting the receiver in a wall or other location outside the fireplace.
CHECKING SYSTEM OPERATION
Remote
Receiver
Velcro Pads
HI
OFF
Figure 17 - Installing Remote Receiver
The millivolt system and individual components may be checked with a millivolt meter having a
CHECK |
| CONNECT | ON/OFF | METER READING | |
TO TEST | METER LEADS | ||||
TEST | CONTACTS | SHOULD BE | |||
| TO TERMINALS | ||||
|
|
|
| ||
|
|
|
|
| |
A | COMPLETE | 2 & 3 | CLOSED | MINIMUM 175mV | |
SYSTEM | |||||
|
|
|
| ||
|
|
|
|
| |
B | THERMOPILE | 1 & 2 | OPEN | MINIMUM 500mV | |
OUTPUT | |||||
|
|
|
| ||
|
|
|
|
|
A.COMPLETE MILLIVOLT SYSTEM CHECK
(“A” Reading - On/Off Switch contacts CLOSED - Control Knob “ON” - Main burner should come ON)
a.If the reading is more than 175 millivolts and the automatic valve still does not come on, replace the control.
b.If the closed circuit reading (“A” reading) is less than 175 millivolts, determine cause for low reading, proceed to Section B below.
B.Thermopile Output Reading Check
(“B” Reading - On/Off Switch contacts OPEN - Main burner OFF)
1. Check gas pressure to the unit. If gas pressure is within minimum and maximum on data plate, then check pilot voltage, 500 millivolts minimum. If the minimum millivolt reading is not obtainable, replace pilot.