Monessen Hearth EYF24 Product Features And Specifications, Manual Pressure, Millivolt Pressure

Models: EYF24 EYF18

1 36
Download 36 pages 14.74 Kb
Page 6
Image 6
PRODUCT FEATURES AND SPECIFICATIONS

PRODUCT FEATURES AND SPECIFICATIONS

NATURAL GAS

 

 

 

 

 

 

Manual Pressure

 

 

Millivolt Pressure

 

 

Regulator Pressure Setting: 4.0" w.c.

Regulator Pressure Setting: 3.5" w.c.

Gas Inlet Pressure:

Max. 10 1/2" w. c.

Pilot Regulator:

3.5" w.c.

 

Min. 5" w.c.

Gas Inlet Pressure:

Max. 10 1/2" w. c.

 

 

 

 

 

Min. 5" w.c.

 

 

 

 

 

 

 

 

 

 

 

Gas Rate

 

 

Model Number

 

Control

Max BTU/Hr

Min BTU/Hr

 

 

EYF24NM

 

Manual

36,000

19,000

 

 

 

 

 

 

 

 

 

EYF24NV

 

Millivolt

36,000

24,000

 

 

EYF18NM

 

Manual

30,000

18,000

 

 

 

 

 

 

 

 

PROPANE/LPG

EYF18NV

 

Millivolt

30,000

26,000

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.

Manual Pressure

 

 

Millivolt Pressure

 

 

Regulator Pressure Setting: 10" w.c.

Regulator Pressure Setting: 10" w.c.

Gas Inlet Pressure:

Maximum 13" w.c.

Gas Inlet Pressure:

Maximum 13" w.c.

 

Minimum 11" w.c.

 

 

Minimum 11" w.c.

 

 

 

 

 

 

 

 

 

 

 

Gas Rate

 

 

Model Number

 

Control

Max BTU/Hr

Min BTU/Hr

 

 

EYF24PM

 

Manual

36,000

25,000

 

 

 

 

 

 

 

 

 

EYF24PV

 

Millivolt

36,000

29,000

 

 

 

 

 

 

 

 

 

EYF18PM

 

Manual

30,000

22,500

 

 

 

 

 

 

 

 

 

EYF18PV

 

Millivolt

30,000

24,500

 

IGNITION CONTROLS

 

 

 

 

 

 

Piezo ignitor allows ignition of the pilot without the use of matches or batteries.

Manual control has three (3) positions:

OFF

-

All gas to the gas logs is shut off at the valve.

IGN

-

Valve position to light/maintain a standing pilot.

HI/LOW

-

Variable position corresponding to desired flame height (heat input)

Millivolt control has four (4) positions:

OFF

-

All gas to the gas logs is shut off at the valve.

IGN

-

Valve position to light/maintain a standing pilot.

ON

-

Valve position to turn ON/OFF log set with remote switch/thermostat.

HI/LOW

-

Variable position to control flame height (heat output).

PILOT

The gas log heater is fitted with a specially designed safety pilot light (ODS assembly) which senses the amount of oxygen available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can only be relit when adequate fresh air is available.

THERMAL GENERATOR

The millivolt gas log pilot is fitted with a millivolt generator to provide power for remote activation.

6

65D1009

Page 6
Image 6
Monessen Hearth EYF24, EYF18 operating instructions Product Features And Specifications, Manual Pressure, Millivolt Pressure