CLEARANCES AND HEIGHT REQUIREMENTS
10"
8"
6"
21/2"
Heat
Resistant
Material
8" 14" 201/2" 245/8" 28"
Heater in |
|
Fireplace or | Example: A mantel may project from the wall a maximum of 21/2" at a mini- |
Firebox | |
| mum of 14" above the opening, and a maximum of 6" at a minimum |
| of 201/2" above the opening. |
Figure 7 - Minimum Mantel Clearance with No Hood -NB18
| 12" |
|
|
| 10" |
|
|
| 8" |
|
|
| 6" |
|
|
Heat | 21/2" |
|
|
Resistant |
|
|
|
Material |
|
|
|
| 8" | 141/2" 185/8" 221/2" 26" | |
| Hood |
|
|
| Heater in |
|
|
| Fireplace or |
|
|
| Firebox | Example: | A mantel may project from the wall a maximum of 21/2" at a |
|
|
| minimum of 8" above the opening, and a maximum of 6" at a mini- |
|
|
| mum of 141/2" above the opening. |
| Figure 8 - Minimum Mantel Clearance with Hood - All Models |
14 | 81D0107 |