Monessen Hearth NB18, NB24 operating instructions Fireplace Preparation

Models: NB18 NB24

1 40
Download 40 pages 3.07 Kb
Page 17
Image 17
FIREPLACE PREPARATION

FIREPLACE PREPARATION

BEFORE FULLY INSTALLING THE UNIT:

Turn OFF the gas supply to the fireplace or firebox.

Seal any fresh air vents and/or ash clean-out doors located on the floor or wall of the fireplace. If left unsealed, drafting may cause pilot outage or sooting. Use a heat resistant sealant. Do not seal the chimney flue damper.

WARNINGManual backgroundManual backgroundManual background

Before installing in a solid fuel burning fireplace, The chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

INSTALLING VENTED APPLICATIONS

Manual and Millivolt controlled gas logs may be installed as a vented decorative log set in compliance with ANSI Z21.60 and National Fuel Gas Code, Section 6.6. Since, the gas logs are operated with the damper open, non-combustible mate- rial and minimum mantel requirements do not apply.

WARNINGManual backgroundManual backgroundManual background

This appliance is for installation only in a solid fuel burning fireplace (masonry fireplace or manufactured fireplace) with a working flue and constructed of noncombustible material.

Exception: DO NOT install this appliance in a factory-built fireplace that includes instructions stating that it has not been tested or should not be used with unvented gas logs. This log set may be installed as a vented log set.

BEFORE INSTALLING THE APPLIANCE:

Turn off gas supply to fireplace or firebox.

Have the fireplace floor and chimney professionally cleaned to remove ashes, soot, creosote or other obstructions. Have this cleaning performed annually after installation.

Seal any fresh air vents or ash clean-out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant.

Install and operate the appliance as directed in this manual.

DAMPER STOP INSTALLATION:

A damper stop must be provided with the unit. Contact your dealer to obtain one. The damper stop must be installed as shown in Figure 13 to prevent full closure of the fireplace damper blade and provide a minimum 29 square inch flue opening.

Damper Stop

Damper

Figure 13 - Damper Stop Installation.

WARNINGManual backgroundManual backgroundManual background

The fireplace and gas logs function as a system. If the fireplace is spilling into the room (check with a match or a smoke stick), reposition the damper clamp until a positive draft is obtained by opening the damper. If negative pressure in home prevents having a positive draft, contact your dealer for assistance.

81D0107

17

Page 17
Image 17
Monessen Hearth NB18, NB24 operating instructions Fireplace Preparation