Morphy Richards Upright Bagless Vacuum Cleaner manual Replacing the belt LM

Models: Upright Bagless Vacuum Cleaner

1 8
Download 8 pages 8.02 Kb
Page 7
Image 7
Replacing the belt LM

73320 Rev 3 17/1/05 2:38 PM Page 7

2Press the handle release pedal and place

the cleaner face down, in the flat position on a soft surface (eg carpet).

3Use a cross-head screwdriver to remove the four screws indicated J.

4Turn the cleaner over.

5While pressing the handle release pedal lift the rear of the top cover, unhook from the front then completely remove the cover K.

Replacing the belt LM

6Lift off the belt cover Û.

7Gently pull the right hand side (belt side) of the floor nozzle outwards and at the same time lift the brush bar out of its location M.

8If the belt has broken, ensure all pieces

are removed. Clean the motor shaft ı.

9Check the brush bar end caps. ˆ

10 Fit the left hand end cap into the floor nozzle.

11 Fit the right hand end cap onto the brush bar.

12 Place one end of the new belt over the motor shaft and the other around the pulley end of the brush.

13 Locate the left hand side of the brush bar first, then while pulling the right hand side of the nozzle gently outwards and stretching the belt, lower the right hand side of the brush into its location.

14 Rotate the brush by hand to ensure it is correctly and securely located.

15 IMPORTANT: Re-fit the belt cover.

16 Replace the top cover, hooking it in at the front first and by pressing the handle release pedal to allow the rear to correctly locate N.

17 Turn the cleaner face down and re-fit and tighten the four fixing screws, do not overtighten.

18 Return the cleaner to its correct working position before re-testing.