Switch settings table of SW1 and SW2 is as follows:

SW1

 

 

 

 

*Full-duplex mode

 

 

 

Off

Half-duplex mode

 

 

 

On

SW2

Pin1 Pin2 Pin3 Pin4

*TxD always enabled

On

Off

X

X

TxD always disabled

Off

Off

X

X

TxD enabled by RTS

Off

On

X

X

*RxD always enabled

X

X

On

Off

RxD enabled by /RTS

X

X

Off

On

Note: ‘ * ‘ means default settings , ‘ X ‘ means don’t care

2.3 LED Indicators

There are LED indicators for TxD, RxD, RTS, and PWR on top of A50/A51. The indicator is not lighted on when not connected with signal or power. On the contrary, it will be lighted on and be in one of the red, green or orange colors.

TxD indicator stands for data transmitting from RS-232 to RS-422/RS-485. It shows green when connected and no data transmitting. It shows orange when connected and transmitting data.

8