Chapter 3

 

 

In the graph, TA, TB, RA and RB could be either from RJ-45 or Terminal Block. The settings of the switches for each A50 (or

A51) are as follows:

SW1 Half-duplex mode

On

SW2

Pin1

Pin2

Pin3

Pin4

TxD enabled by RTS

Off

On

X

X

RxD enabled by / RTS

X

X

Off

On

3.3 Simplex/Transmit, Receive

Simplex configuration means that more than two devices (Max. 10 for RS-422; Max. 32 for RS-485) can be linked all together to communicate through many A50/A51 devices. Its configuration is like the Multidrop's, but the master device can talk only and the slave devices can listen only.