Moxa Technologies CP-114 Series user manual Connection Cable and Cable Wiring, DCE Device

Models: CP-114 Series

1 55
Download 55 pages 16.41 Kb
Page 43
Image 43

Connection Cable and Cable Wiring

Type 2: To connect Industio CP-114 Series to a DCE device.

CP-114

Modem

or any DCE Device

CP-114

 

 

DCE Device

DB9 Male

 

 

DB25 Female

RxD

2

2

RxD

TxD

3

3

TxD

CTS

8

4

CTS

RTS

7

5

RTS

DTR

4

6

DTR

DSR

6

20

DSR

GND

5

7

GND

DCD

1

8

DCD

Type 3: To connect Industio CP-114 Series to a DTE with 3-pin wiring.

If the [Hardware flow control] feature is set to “ON”, you must loop back (or short) the RTS with CTS and the DSR with DTR, DCD on the MOXA site.

If [Hardware flow control] feature is set to “OFF”, you could just leave RTS, CTS, DSR, DTR, DCD open, ignoring the connection indicated in dash-lines.

CP-114

PC COM2 port, Serial Printer, Terminal, or any DTE Device

CP-114

DB9 Male

TxD

RxD

GND

RTS

CTS

DTR

DSR

DCD

CP-114

CP-114

DB9 Male

TxD

RxD

GND

RTS

CTS

DSR

DTR

DCD

 

 

DTE Device

 

 

DB25 Male

3

2

TxD

2

3

RxD

5

7

GND

7

4

RTS

8

5

CTS

4

20

DTR

6

6

DSR

1

8

DCD

 

 

PC COM2 port, Serial Printer,

 

 

Terminal, or any DTE device

 

 

DTE Device

 

 

DB9 Male

3

3

TxD

2

2

RxD

5

5

GND

7

7

RTS

8

8

CTS

6

6

DSR

4

4

DTR

1

1

DCD

Industio CP-114 User's Manual 5-3

Page 43
Image 43
Moxa Technologies CP-114 Series user manual Connection Cable and Cable Wiring, DCE Device