Connection Cable and Cable Wiring
Type 2: To connect Industio
Modem
or any DCE Device
|
| DCE Device | |
DB9 Male |
|
| DB25 Female |
RxD | 2 | 2 | RxD |
TxD | 3 | 3 | TxD |
CTS | 8 | 4 | CTS |
RTS | 7 | 5 | RTS |
DTR | 4 | 6 | DTR |
DSR | 6 | 20 | DSR |
GND | 5 | 7 | GND |
DCD | 1 | 8 | DCD |
Type 3: To connect Industio
If the [Hardware flow control] feature is set to “ON”, you must loop back (or short) the RTS with CTS and the DSR with DTR, DCD on the MOXA site.
If [Hardware flow control] feature is set to “OFF”, you could just leave RTS, CTS, DSR, DTR, DCD open, ignoring the connection indicated in
PC COM2 port, Serial Printer, Terminal, or any DTE Device
DB9 Male
TxD
RxD
GND
RTS
CTS
DTR
DSR
DCD
DB9 Male
TxD
RxD
GND
RTS
CTS
DSR
DTR
DCD
|
| DTE Device |
|
| DB25 Male |
3 | 2 | TxD |
2 | 3 | RxD |
5 | 7 | GND |
7 | 4 | RTS |
8 | 5 | CTS |
4 | 20 | DTR |
6 | 6 | DSR |
1 | 8 | DCD |
|
| PC COM2 port, Serial Printer, |
|
| Terminal, or any DTE device |
|
| DTE Device |
|
| DB9 Male |
3 | 3 | TxD |
2 | 2 | RxD |
5 | 5 | GND |
7 | 7 | RTS |
8 | 8 | CTS |
6 | 6 | DSR |
4 | 4 | DTR |
1 | 1 | DCD |
Industio