Redundancy Protocol
Setting Description Factory Default
Turbo Ring Select this item to change to the
Turbo Ring configuration page.
Turbo Ring V2 Select this item to change to the
Turbo Ring V2 configuration page.
RSTP (IEEE
802.1W/1D) Select this item to change to the
RSTP configuration page.
None Ring redundancy is not active
None
Set as Master
Setting Description Factory Default
Enabled Select this EDS as Master
Disabled Do not select this EDS as Master Not checked
Redundant Ports
Setting Description Factory Default
1st Port Select any port of the EDS to be
one of the redundant ports. EDS-405A: port 4
EDS-408A: port 7
2nd Port Select any port of the EDS to be
one of the redundant ports. EDS-405A: port 5
EDS-408A: port 8
Enable Ring Coupling
Setting Description Factory Default
Enable Select this EDS as Coupler
Disable Do not select this EDS as Coupler Not checked
Coupling Port
Setting Description Factory Default
Coupling Port Select any port of the EDS to be the
coupling port EDS-405A: port 2
EDS-408A: port 5
Coupling Control Port
Setting Description Factory Default
Coupling Control Port Select any port of the EDS to be the
coupling control port EDS-405A: port 3
EDS-408A: port 6