EDS-408A/405A Series User’s Manual Featured Functions

3-48

2. Activate your settings
After configuring, you will need to activate your EDS’s Relay Event Types.
Relay Warning Events Settings
NOTE: The user interface for the EDS-408A shows 8 ports.

Event Types

Event Types can be divided into two basic groups: System Events and Port Events. System
Events are related to the overall function of the switch, whereas Port Events are related to the
activity of a specific port.
The EDS supports one relay output. You can configure which relay output is related to which
events. This helps administrators identify the importance of the different events.
System Event Warning Relay output is triggered when…
Power Transition (OnÆOff) EDS is powered up.
Power Transition (OffÆOn) EDS is powered down.
Turbo Ring Break (Ring Master
Only) When the EDS-408A/405A is the
Master of this Turbo Ring, and the
Turbo Ring is disconnected.
NOTE If the Turbo Ring Switch function is enabled, and the Turbo Ring DIP Switch is set to “ON”, the
Turbo Ring Break Event cannot be changed. If not, the Turbo Ring Break Event can be set by
using a web browser.
NOTE The Turbo Ring Break Warning will be automatically enabled when the following configuration
is set:
1. Turbo Ring DIP Switch functions are enabled.
2. The Hardware Turbo Ring DIP Switch is set to “ON”.
3. The Master DIP Switch is set to “ON”.
Please refer to “Configuring Basic SettingsTurbo Ring DIP Switch” for more details.