EDS-408A/405A Series User’s Manual Featured Functions

3-46

Port Event Warning e-mail is sent when…
Link-on The port is connected to another device.
Link-off The port is disconnected (e.g., the cable is pulled
out, or the opposing device shuts down).
Traffic-Overload The port’s traffic surpasses the Traffic-Threshold for
that port (provided this setting is Enabled).
Traffic-Threshold (%) Enter a nonzero number if the port’s
Traffic-Overload setting is Enabled.
Traffic-Duration (sec.)
A Traffic-Overload warning is sent every
Traffic-Duration seconds if the average
Traffic-Threshold is surpassed during that time
period.
NOTE The Traffic-Overload, Traffic-Threshold (%), and Traffic-Duration (sec.) Port Event settings
are related. If you Enable the Traffic-Overload event, then be sure to enter a nonzero
Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds.
NOTE Warning e-mail messages will have the sender field in the form:
Moxa_EtherDevice_Switch_0001@Switch_Location
where Moxa_EtherDevice_Switch is the default Switch Name, 0001 is EDS’s serial number, and
Switch_Location is the default Server Location.
Refer to the Basic Settings section to see how to modify Switch Name and Switch Location.
Email Settings