EDS-518A Series User’s Manual

Featured Functions

 

 

 

 

 

 

 

 

 

System Events

Warning e-mail is sent when…

 

 

 

 

Switch Cold Start

Power is cut off and then reconnected.

 

 

 

 

Switch Warm Start

EDS-518A is rebooted, such as when network

 

 

 

 

 

parameters are changed (IP address, subnet mask,

 

 

 

 

 

etc.).

 

 

 

 

Power Transition (OnÆOff)

EDS-518A is powered down.

 

 

 

 

Power Transition (OffÆOn)

EDS-518A is powered up.

 

 

 

 

DI1 (OnÆOff)

Digital Input 1 is triggered by on to off transition

 

 

 

 

DI1 (OffÆOn)

Digital Input 1 is triggered by off to on transition

 

 

 

 

DI2 (OnÆOff)

Digital Input 2 is triggered by on to off transition

 

 

 

 

DI2 (OffÆOn)

Digital Input 2 is triggered by off to on transition

 

 

 

 

Configuration Change Activated

A configuration item has been changed.

 

 

 

 

Authentication Failure

An incorrect password is entered.

 

 

 

 

Comm. Redundancy Topology

Spanning Tree Protocol switches have changed their

 

 

 

 

Changed

position (applies only to the root of the tree).

 

 

 

 

 

The Master of the Turbo Ring has changed or the

 

 

 

 

 

backup path is activated.

 

 

 

 

 

 

 

 

 

Port Events

Warning e-mail is sent when…

 

 

 

 

Link-ON

The port is connected to another device.

 

 

 

 

Link-OFF

The port is disconnected (e.g., the cable is pulled out,

 

 

 

 

or the opposing device shuts down).

 

 

 

 

 

 

 

 

 

Traffic-Overload

The port’s traffic surpasses the Traffic-Threshold for

 

 

 

 

that port (provided this item is Enabled).

 

 

 

 

 

 

 

 

 

Traffic-Threshold (%)

Enter a non-zero number if the port’s

 

 

 

 

Traffic-Overload item is Enabled.

 

 

 

 

 

 

 

 

 

 

A Traffic-Overload warning is sent every

 

 

 

 

Traffic-Duration (sec.)

Traffic-Durationseconds if the average

 

 

 

 

Traffic-Threshold is surpassed during that time

 

 

 

 

 

 

 

 

 

 

period.

 

 

 

 

 

NOTE

The Traffic-Overload,Traffic-Threshold (%), and Traffic-Duration (sec.) Port Event items

 

 

are related. If you Enable the Traffic-Overload event, then be sure to enter a non-zero

 

 

Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds.

 

 

 

 

 

 

 

NOTE

Warning e-mail messages will have the sender field formatted in the form:

 

 

 

MOXA_EtherDevice_Switch_0001@Switch_Location

 

 

where MOXA_EtherDevice_Switch is the default Switch Name, 0001 is EDS-518A’s serial

 

 

number, and Switch_Location is the default Server Location.

 

 

Refer to the Basic Settings section to see how to modify Switch Name and Switch Location.

 

 

 

 

 

 

3-54