Ethernet Interface
Number of Ports 2 (1 IP) 2 (1 IP) 2 (1 IP) 2 (1 IP)
Speed 10/100 Mbps 10/100 Mbps 10/100 Mbps 10/100 Mbps
Connector RJ45 RJ45 RJ45 RJ45
Magnetic Isolation
Protection 1�5 KV 1�5 KV 1�5 KV 1�5 KV
Serial Interface
Number of Ports 1122
Serial Standards RS-232/422 RS-232/422 RS-232/422 RS-232/422
Connectors DB9-M (RS-232), TB (RS-422) DB9-M (RS-232), TB (RS-422) DB9-M DB9-M
ESD Protection 15 KV 15 KV 15 KV 15 KV
RS-485 Data Direction
Control ADDC® ADDC® ADDC® ADDC®
Serial Communication
Parameters Data Bits: 7, 8; Stop Bits: 1, 2; Parity: None, Even, Odd, Space, Mark
Parity None, Even, Odd, Space, Mark
Flow Control RTS/CTS, DTR/DSR
Baudrate 50 bps to 921�6 Kbps
Software
Operation Modes --- --- --- ---
Utilities MGate™ Manager Suite for Windows 98, ME, NT, 2000, XP, 2003, Vista
Smart Routing √√√√
Serial Redirection --- --- √ √
Priority Control --- --- --- ---
Ethernet Protocol CIP (PCCC) on Ethernet/IP CIP (PCCC) on Ethernet/IP CIP (PCCC) on Ethernet/IP CIP (PCCC) on Ethernet/IP
Serial Protocol DF1 Full-duplex DF1 Full-duplex DF1 Full-duplex DF1 Full-duplex
Physical Characteristics
Housing Plastic Plastic Plastic Plastic
Dimensions 29 x 89�2 x 118�5 mm 29 x 89�2 x 118�5 mm 29 x 89�2 x 118�5 mm 29 x 89�2 x 118�5 mm
Environmental Limits
Operating Temperature 0 to 55°C or -40 to 75°C 0 to 55°C or -40 to 75°C 0 to 55°C or -40 to 75°C 0 to 55°C or -40 to 75°C
Operating Humidity 5 to 95% RH 5 to 95% RH 5 to 95% RH 5 to 95% RH
Storage Temperature -20 to 85°C -20 to 85°C -20 to 85°C -20 to 85°C
Power Requirements
Input Voltage 12 to 48 VDC 12 to 48 VDC 12 to 48 VDC 12 to 48 VDC
Power Connector Terminal block Terminal block Terminal block Terminal block
Regulatory Approvals
EMC CE (EN55022 Class A and EN55024), FCC Part 15 Subpart B Class A
Safety UL (UL60950-1), LVD (EN60950-1)
Hazardous Location UL/cUL Class 1 Division 2 Groups A, B, C, D; ATEX Class 1 Zone 2
Shock IEC60068-2-27
Freefall IEC60068-2-23
Vibration IEC60068-2-6
Marine --- --- --- ---
EMS
EN61000-4-2 (ESD): Level 3
EN61000-4-3 (RS): Level 3
EN61000-4-4 (EFT): Level 4
EN61000-4-5 (Surge): Level 3
EN61000-4-6 (CS): Level 3
EN61000-4-8: Passed
EN61000-4-11: Passed
EN61000-4-12: Passed
Reliability