ELECTRICAL SCHEMATICS

6

CAM 1

TO CUSTOMER RECEPTACLE

115V 60Hz

BLK WHT

GND

1

2

00012

CUSTOMER TO SUPPLY RATED VOLTAGE/PHASE/Hz, AS SPECIFIED PER ORDER, TO DISCONNECT SWITCH.

ALL POWER SUPPLIED TO EACH CONNECTION POINT MUST COMPLY WITH ALL LOCAL ELECTRICAL CODES.

TTS 10

WHTR

 

2

8

2

CLT

 

NC

7

NC

 

8

8

TM

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

13

 

BLU START CW

 

9

9 SRC 12

3

 

 

RED START CCW

24

2

9

 

 

 

 

 

 

2

 

1

 

 

15

 

15

BLK

MAIN

 

 

 

 

 

 

 

 

 

 

3

 

 

 

CAM

 

2

 

WHT

 

 

8

 

 

 

4

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

20

DP

2

 

5

 

 

 

 

 

 

 

 

 

 

CAM

D V

2

 

 

 

 

8

 

 

 

 

 

NC

 

2

 

 

 

 

 

16

 

 

 

 

 

 

 

21

 

2

 

 

 

 

8

CAM

DM

 

 

 

 

 

NC

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

17

(IF USED)

 

 

 

 

 

 

CAM

RM

2

 

 

 

 

8

 

 

 

 

 

NC

 

 

 

 

 

BLK

BLACK

CLT

CYCLE ON LIGHT

 

PSDR

PRIME SWITCH DETERGENT, RINSE

BLU

BLUE

DM

DETERGENT MOTOR

RM

RINSE MOTOR

(IF USED)

BTS

BOOSTER THERMOSTAT

DP

DRAIN PUMP

(IF USED)

SRC

CURRENT OPERATED START RELAY COIL

CAM 1

HOMING

DS

DOOR SWITCH

 

TM

TIMER MOTOR

 

CAM 2

PUMP MOTOR

DV

DRAIN VALVE

 

TP

THERMAL PROTECTOR

CAM 3

PUMP MOTOR REVERSING

EW/D

EXTENDED WASH/DELIME

TTS

TANK HEATER THERMOSTAT

CAM 4

DRAIN

FV

FILL VALVE

 

WHT

WHITE

 

CAM 5

FILL

GND

GROUND

 

WHTR

WATER HEATER

 

CAM 6

RINSE

GRN

GREEN

 

 

 

 

CAM 7

DETERGENT

HLTS

HIGH LIMIT THERMOSTAT

 

 

 

CAM 8

AUTO-FILL DRAIN

MSW

MAIN SWITCH ON/FILL OFF/DRAIN

 

 

 

Figure 19 - Electrical Diagram, 501-HTN (For machines built prior to S/N 6984)

48

Page 54
Image 54
Moyer Diebel 501-LT technical manual Electrical Diagram, 501-HTN For machines built prior to S/N