Pin

Signal name

Function

1

VCC

Power Supply

2

SDO_TDO

Serial Data Out

3

SDI_TDI

Serial Data In

4

ISPEN#

Programming Enable

5

KEY

Keypin

6

MODE_TMS

Programming Mode

7

GND

Ground

8

SCLK_TCK

Serial Clock

Table 30 Pinout Lattice Programming Interface

4.24Battery

The RTC on the COM Express module is buffered with a socketed battery on the base board.

In order to clear the CMOS memory, the battery voltage to the COM Express module can be disconnected via jumper J1101.

Type of battery:

2032

Battery socket:

Renata SMTU2032-1

4.25Beeper

A piezo signal generator is implemented for acoustic signals.

Type:Digisound F/DGX05P

4.26Power Button

For switching the system on a Power push button has been implemented.

The PWR_BTN# signal is low-active and is connected directly to the corresponding pin of the COM Express module.

Type:

C&K JTP-1230F

4.27Reset Button

There is a push button for resetting the system.

The RESET# signal is low-active and is connected to the SYS_RESET#- pin of the COM Express module.

Type:

C&K JTP-1230F