These following pieces of trim may be used in cases where the edge of the flooring does not butt completely up against the wall. The UniPanels, as mentioned in previous sections, can also be cut to meet up against the wall to finish the flooring matrix.

(1)When the residual space is less than 2.36”(6 cm) in width: Use Edge Rail (AD-623). Fasten Edge Rail through the pre-punched holes at both ends to the UniPanel or SubPanels with type-s or flat-head screws (Drawing D611).

(2)When the residual space is a width of 2.36”- 5.11”(6 cm ~ 13 cm): Use Wall Rail (AD-630) as a spacer. First butt the Wall Rail directly against the last UniPanel or SubPanels. Then, as described in step (1), fasten Edge Rail to take up the remaining gap (Drawing D611).

(3)Distance between 5.11”- 8.66”(13 cm ~ 22 cm): Use a row of SubPanels (1/4 of UniPanel) as a spacer. Butt the SubPanels against the last UniPanels. Connect the SubPanels by Half-Connector at trench. Then, fill the balance by single use or combined use of Edge Rail and/or Wall Rail to finish the remaining gap (Drawing D611).

(4)The final space left in the corner after use of the last Edge Rail: Use Corner Rail (AD-629), which has short segments that can be broken off, and each segment has a pre-punched hole to allow fastening to adjoining parts. (Drawing D611)

Ramp Rail: When installing ramp with Ramp Rail, cut Rail to length then insert between Ramp section and first UniPanels as shown. Pre-drill holes as needed on both the flat flange and the sloped flange, then secure it with flat-head screws to both the adjacent UniPanels and the Ramp sections. Carpet tile edges are tucked into the channels on top of the Rail. This provides easy rigidity and a finished look. The visible aluminum strip also serves as a ready reminder of the sloping (Drawing D612).

Edge Trimmers are used to trim and finish the ConnectFloor installation along the walls. They are set down on the small recessed “shelf” –on all four sides of the UniPanels designed to receive Flank Caps— along the starting wall to bring up the finished floor to a uniform elevation. In most cases, this edge trim is not used in typical installations. (Drawing D611).

D611D611

(Single or Double)

7

Page 8
Image 8
Multi-Link ConnectFloor, AD-600 manual D611D611