Chapter 6 – Callback Security

Front Panel Method

1.Turn on the modem.

2.Starting at the STATUS LCD, press the following buttons on the front panel to turn callback security on and off:

To turn on callback security, press È, È, Æ, È, È, Æ, Æ to display the CALLBACK ON? option, and then press the Enter button to select the option. When remote callback security is turned on, each caller is asked to enter a password, then is disconnected and called back by the modem. Also, dialing number locations 0–3, for use with the DS=y dialing command, are replaced by callback dialing number locations 1–30.

To turn off callback security, press È, È, Æ, È, È, Æ, Æ, Æ to display the CALLBACK OFF? option, and then press the Enter button to select the option. Callers no longer need a password to connect to the modem, the modem is unable to call them back, and stored dialing number locations 0–3 become available.

Assigning Callback Passwords

AT Command Method

1.Open a terminal program, such as HyperTerminal.

2.To store a callback password for the first callback memory location, type

AT#CBP01=xxxxxxxxxx, where xxxxxxxxxx is the first password, and press ENTER. The password must be six to ten characters in length.

3.To store a callback password for the second callback memory location, type AT#CBP02=xxxxxxxxxx, where xxxxxxxxxx is the second password, and press ENTER. Note that the memory location number in the command is incremented by one.

4.Repeat as many times as necessary, up to memory location 30, until all passwords have been entered.

Front Panel Method

1.Turn on the modem.

2.Starting at the STATUS LCD, press the following buttons on the front panel: È, È, Æ, È, È, Æ, È, Æ. The ENTER PASSWORD #1? LCD appears.

3.Press the Enter button on the front panel to select callback memory location 1. The ENTER PASSWORD LCD appears.

4.Press the ÇÅ or È button several times to select the first letter in the password.

5.Press the Æ button to go to the next letter in the password. Note: To backspace or to cancel an entry, press Æ several times.

6.The password must be six to ten characters in length. Repeat steps 4 and 5 until the password is entered, and then press the Enter button to store it. The PASSWORD STORED LCD should appear.

7.Press the Enter button again to go to the PASSWORD SETUP LCD.

8.Press Æ, Æ to go to the ENTER PASSWORD #2? LCD.

9.Repeat steps 3–7 to enter the next password.

10.Repeat as many times as necessary, up to memory location 30, until all passwords have been entered.

Warning: There is no way to review an entry to confirm that it has been entered correctly. If you attempt to look at a password entry by pressing the Enter button for an ENTER PASSWORD #n? LCD, it is possible to accidentally erase the entry.

Multi-Tech Systems, Inc. MT5600BA-V92 User Guide

35

Page 35
Image 35
Multi-Tech Systems MT5600BA-V92 manual Assigning Callback Passwords, Front Panel Method

MT5600BA-V92 specifications

Multi-Tech Systems MT5600BA-V92 is a versatile communication device designed for efficient data transmission over telephone lines. It is highly regarded for its reliability and performance in various applications, including point-of-sale transactions, remote monitoring, and data acquisition. One of the key features of the MT5600BA-V92 is its ability to operate at data rates of up to 56 Kbps. This high-speed modem ensures rapid data transfer, making it suitable for businesses that require quick and efficient communication.

The device supports V.92 technology, which enhances the performance of dial-up connections. V.92 provides features like cheaper call setup times, reduced latency, and improved upload speeds compared to older standards. This makes the MT5600BA-V92 an ideal choice for users who need enhanced data performance without investing in more complex networking infrastructure.

Another significant characteristic of the MT5600BA-V92 is its analog communication capabilities. The modem utilizes standard analog telephone lines for connectivity, allowing easy integration into existing telephony systems. This compatibility ensures that businesses can leverage their current infrastructure without needing substantial upgrades.

The MT5600BA-V92 integrates several features for improved functionality, including error correction and data compression technologies. These features enhance the reliability of data transmission by ensuring that lost or corrupted data packets are retransmitted, while compression reduces the amount of data sent over the line, further optimizing performance.

The modem is designed with user-friendliness in mind; it features a straightforward installation process and an intuitive configuration interface. Furthermore, it is compact and robust, making it suitable for diverse environments ranging from retail outlets to industrial applications.

The MT5600BA-V92 is also known for its durability and long life cycle, which is crucial for businesses that rely on continuous operations. Additionally, its ability to operate effectively in various conditions solidifies its position as a dependable communication solution.

In summary, the Multi-Tech Systems MT5600BA-V92 is an advanced modem that combines high-speed data transmission, analog compatibility, and robust error correction features. Its reliable performance and user-friendly design make it an excellent choice for businesses looking to enhance their communication capabilities while utilizing existing telephone infrastructure.