Chapter 1 – Product Description and Features
Multi-Tech Systems, Inc. MT5600BA-V92 User Guide 7
Operating Temperature 32°–120° F (0°–50° C) ambient under closed conditions
Humidity Range 25–85% (non-condensing)
Storage Temperature 14°– 185° F (-10° to +85° C)
Power Requirement 100 to 240 VAC, 50/60 Hz
Power Consumption 12 W @ 0.1 A typical
Dimensions 6.2" wide × 1.4” high x 9.0" deep (15.8 cm × 3.6 cm x 22.9 cm)
Weight 2 lbs. (0.9 kg)
Limited Warranty 5 years
Certifications CE Mark
EMC: FCC Part 15 Class B, EN 55024
Safety: cUL, EN 60950, UL 60950
Telecom: CS03, FCC Part 68, TBR21
Intelligent Features Plug and Play; remote configuration for centralized setup and
management; pass-through and fixed callback security; AT command
compatible; autodial, redial, repeat dial; pulse or tone dial; dial pauses;
auto answer; caller ID; adaptive line probing; automatic symbol and
carrier frequency during start-up, retrain, and rate renegotiation; DTMF
detection; call status display, auto-parity and data rate selection;
keyboard- and front panel-controlled modem options; monitor and LCD
displays for modem options; non-volatile memory; storage of up to four
command strings or telephone numbers of up to 40 characters each.