BASIC OPERATIONS

Data bits: 8

Parity: none

Stop bit: 1

Flow control: hardware

To confirm you are communicating with the device:

Type AT and press Enter.

If the device responds with OK, you are communicating with the device.

Verifying Signal Strength

To verify the device signal strength, enter:

AT+CSQ

The command indicates signal quality, in the form: +CSQ: <rssi>,<ber>

Where:

<rssi>

Received signal strength indication.

0

(-113) dBm or less

1

(-111) dBm

2-30

(-109) dBm - (-53) dBm / 2 dBm per step

31

(-51) dBm or greater

99

Not known or not detectable

<ber>

Bit error rate, in percent

0

Less than 0.2%

1

0.2% to 0.4%

2

0.4% to 0.8%

3

0.8% to 1.6%

4

1.6% to 3.2%

5

3.2% to 6.4%

6

6.4% to 12.8%

7

More than 12.8%

99

Not known or not detectable

QuickCarrierTM USB-D EV-DO MTD-EV3 User Guide

15

Page 15
Image 15
Multi-Tech Systems MTD-EVe manual Verifying Signal Strength, At+Csq