Multi Tech Equipment MVH306DS2 manual System Diagnostics to Detect Operational Abnormalities

Models: MVH306DS2 MVH306DSCPAS

1 80
Download 80 pages 37.59 Kb
Page 23
Image 23

operation

System Diagnostics to Detect Operational Abnormalities

Detection of ground trouble and soft ground

1.For a case of unstable ground or soft ground (soil containing high clay content) for which the use of this machine is not suitable, only the green and red LEDs will be on (Figure 27), with no yellow LED's on.

If this occurs it would be challenging to achieve the desired compaction results. Check to make sure the ground conditions are prepared to specification before proceeding with the compaction process.

GREEN

GROUND TROUBLE

OR

LED ON

SOFT GROUND

 

 

RED

 

LED ON

Figure 27. Ground Trouble or Soft Ground

Detection of Vibration Abnormality

2.When appropriate vibration frequency cannot be achieved during operation due to improper engine RPMs (Figure 28) the green LED will flash. When this occurs check the engine RPMs and the V-belt tension as it could be loose.

VIBRATION ABNORMALITY DUE TO

IMPROPER ENGINE RPM

GREEN LED

FLASHING

Figure 28. Vibration Abnormality

Improper Engine RPM's

Function to Detect Electric System Abnormality

Sensor wire disconnection (between acceleration sensor and sensor panel)

3.If red and green LEDs are flashing alternately as shown in Figure 29 then please check the sensor wire because there is a possibility that it is disconnected.

RED LED

FLASHING

GREEN LED

FLASHING

Figure 29. Sensor Wire Disconnection

Power cable disconnection (between battery and sensor panel)

4.If there are no LEDs on or flashing even when the key switch is turned on then please check the power cable because there is a possibility it is disconnnected.

mvh306ds2/dsCPAs pLATE COMPACTOR • operation and parts manual — rev. #7 (02/04/14) — page 23

Page 23
Image 23
Multi Tech Equipment MVH306DS2, MVH306DSCPAS manual System Diagnostics to Detect Operational Abnormalities