BP-25H CE GASOLINEVIBRATOR — ENGINE SHUTDOWN

Stopping The Engine

Normal Shutdown

1.Remove the flexible shaft and vibrator head from the mix.

2.Rotate the throttle grip CCW to the “TURTLE” position (Figure 18) and run the engine for three minutes at idle

speed.

CCW ROTATION

 

 

DECREASES

 

ENGINE SPEED

 

(IDLE)

THROTTLE

GRIP

Figure 18.Throttle Lever (Turttle/Idle)

3.Press and hold the engine KILL switch (Figure 19) to shutdown the engine . The engine kill switch is located underneath the metal square box on the handle.

Figure 19. Engine Kill Switch

4.Place the fuel shut-off lever (Figure 20) in the OFF position.

Figure 20. Fuel Valve Lever (OFF)

5.Place the engine ON/OFF Switch (Figure 21) in the OFF position.

Figure 21. Ignition ON/OFF Switch (OFF Position)

Emergency Showdown

1. Press and hold the engine KILL switch (Figure 19) .

BP-25H CE GASOLINE VIBRATOR — OPERATION MANUAL— REV. #4 (12/19/07) — PAGE 21

Page 21
Image 21