DCA-20SPX — RULES FOR SAFE OPERATION

ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using generators.

NEVER leave the generator unattended, turn off engine when unattended.

Unauthorized equipment modifications will void all warranties. ALWAYS ensure generator is on level ground before use.

DO NOT place hands or fingers inside generators engine compartment when engine is running.

NEVER run engine without air cleaner. Severe engine damage may occur.

NEVER change or adjust the engine speed which has been set at the factory prior to shipping.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

HighTemperatures – Always stop engine and allow the engine to cool before adding fuel, oil or performing service and maintenance functions. Contact with hot! components can cause serious burns.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and replace any broken parts immediately.

ALWAYS replace any worn or damaged warning decals.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and un-authorized personnel.

Power Cord Safety

NEVER let power cables or cords lay in water.

NEVER stand in water while AC power from the generators is being transfer to a load.

NEVER use a defective or frayed power cable. Check the cable for cuts in the insulation.

NEVER use a extension cord that is frayed or damaged where the insulation has been cut.

ALWAYS make certain that proper power or extension cord has been selected for the job See Table 4.

Grounding Safety

ALWAYS make sure that electrical circuits are properly grounded per the National Electrical Code (NEC) and local codes before operating generator. Severe injury or death! by electrocution can result from operating an ungrounded generator.

ALWAYS make sure the generators are properly grounded to a suitable earth ground (GROUND ROD). See installation in this manual.

NEVER use gas piping as an electrical ground.

The electrical voltage required to operate the generator can cause severe injury or even death through physical contact with live circuits. Turn all circuit breakers OFF before performing maintenance on the generator.

Dispose of hazardous waste properly. Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

ALWAYS allow the machine a proper amount of time to cool before servicing.

ALWAYS service air cleaner frequently to prevent engine malfunction.

ALWAYS disconnect the NEGATIVE battery terminal before performing service on the generator.

Follow all battery safety guidelines listed in this manual when handleing or servicing the generator.

DCA-20SPX— OPERATION AND PARTS MANUAL — REV. #2 (04/14/10) — PAGE 11

Page 11
Image 11
Multiquip operation manual DCA-20SPX Rules for Safe Operation, Maintenance Safety

DCA-20SPX specifications

The Multiquip DCA-20SPX is a versatile and robust portable generator designed to meet the power demands of various applications, from construction sites to outdoor events. Boasting a compact and lightweight design, this generator is engineered to offer exceptional performance in a multitude of environments.

One of the standout features of the DCA-20SPX is its reliable power output. Powered by a reliable diesel engine, the generator delivers a continuous output of 20 kVA, making it suitable for both small and medium-sized operations. This generator is particularly favored for its efficient fuel consumption, allowing users to operate for extended periods without frequent refueling.

Another key characteristic of the DCA-20SPX is its advanced inverter technology, ensuring stable and clean power suitable for sensitive electronic equipment. This technology effectively minimizes harmonic distortion, providing an output that is safe for powering computers, medical devices, and other electronics requiring a stable power supply.

The generator’s user-friendly control panel is designed for ease of operation. It features clear displays and intuitive controls, allowing operators to monitor key performance indicators like voltage, frequency, and hour meter with ease. Additionally, the panel includes multiple outlet options, accommodating various plug types, which enhances its versatility on job sites.

Durability is a hallmark of the Multiquip DCA-20SPX’s design. The generator is built with a sturdy steel frame and finished with weather-resistant coatings, enabling it to withstand the rigors of outdoor usage in challenging conditions. Its integrated handling features, such as fork pockets and lifting eyes, also facilitate easy transport and setup.

For user safety, the DCA-20SPX is equipped with essential protection features. It includes low oil shutdown, overload protection, and thermal shutdown, which collectively safeguard the generator from potential damage, ensuring long operational life and reliability.

Overall, the Multiquip DCA-20SPX excels in providing reliable energy solutions for various applications, adorned with advanced technologies, user-friendly features, and a robust build. Whether for construction, emergency power supply, or remote events, it stands as a trusted ally for those who require efficient and dependable power on demand.