DCA-20SPX — MAINTENANCE

TABLE 11. INSPECTION/MAINTENANCE

 

10 Hrs

250 Hrs

500 Hrs

 

1000 Hrs

 

DAILY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Engine Fluid Levels

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Air Cleaner

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Battery Acid Level

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Fan Belt Condition

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for Leaks

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for Loosening of Parts

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace Engine Oil and Filter * 1

 

 

X

 

 

 

 

 

 

 

 

 

 

 

ENGINE

Clean Air Filter

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Check Fuel Filter/Water Seperator Bowl

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean Unit, Inside and Outside

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Change Fuel Filter

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Clean Radiator and Check Coolant Protection Level*2

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Replace Air Filter Element * 3

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Check all Hoses and Clamps * 4

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

Clean Inside of Fuel Tank

 

 

 

 

 

X

 

 

 

 

 

 

 

 

GENERATOR

Measure Insulation Resistance Over 3M ohms

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Check Rotor Rear Support Bearing

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

Replace engine oil anf filter at 100 hours, first time only.

 

 

 

 

 

*2

Add "Supplemental Coolant Addatives (SCA'S)" to recharge the engine coolant.

 

 

 

 

*3 Replace primary air filter element when restriction indicator shows a vaccum of 625 mm (25 in. H20).

 

 

*4

If blowby hose needs to be replaced, ensure that the slope of the bloby hose is at least a 1/2 inch per foot, with

 

 

no sags or dips that could collect moisture and/or oil.

 

 

 

 

 

General Inspection

Prior to each use, the generator should be cleaned and inspected for deficiencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel, oil, and coolant leaks.Use Table 11 as a general maintenance guideline Engine Side (Refer to the Engine Instruction Manual)

Air Cleaner

Every 250 hours: Remove air cleaner element and clean the heavy duty paper element with light spray of compressed air. Replace the air cleaner as needed.

Air Cleaner with Dust Indicator

This indicator is attached to the air cleaner. When the air cleaner element is clogged, air intake restriction becomes greater and the dust indicator signal shows RED meaning the element needs changing or service. After changing the air element, press the dust indicator button to reset the indicator.

Service Daily

If the engine is operating in very dusty or dry grass conditions, a clogged air cleaner will result. This can lead to

aloss of power, excessive carbon buildup in the combustion chamber and high fuel consumption. Change air cleaner more frequently if these conditions exists.

Fuel Addition

Add diesel fuel (the grade may vary according to season and locations).

Removing Water from the Fuel Tank

After prolonged use, water and other impurities accumulate in the bottom of the tank. Occasionally inspect the fuel tank for water contamination and drain the contents if required.

During cold weather, the more empty volume inside the tank, the easier it is for water to condense. This can be reduced by keeping the tank full with diesel fuel.

DCA-20SPX— OPERATION AND PARTS MANUAL — REV. #2 (04/14/10) — PAGE 39

Page 39
Image 39
Multiquip operation manual DCA-20SPX Maintenance

DCA-20SPX specifications

The Multiquip DCA-20SPX is a versatile and robust portable generator designed to meet the power demands of various applications, from construction sites to outdoor events. Boasting a compact and lightweight design, this generator is engineered to offer exceptional performance in a multitude of environments.

One of the standout features of the DCA-20SPX is its reliable power output. Powered by a reliable diesel engine, the generator delivers a continuous output of 20 kVA, making it suitable for both small and medium-sized operations. This generator is particularly favored for its efficient fuel consumption, allowing users to operate for extended periods without frequent refueling.

Another key characteristic of the DCA-20SPX is its advanced inverter technology, ensuring stable and clean power suitable for sensitive electronic equipment. This technology effectively minimizes harmonic distortion, providing an output that is safe for powering computers, medical devices, and other electronics requiring a stable power supply.

The generator’s user-friendly control panel is designed for ease of operation. It features clear displays and intuitive controls, allowing operators to monitor key performance indicators like voltage, frequency, and hour meter with ease. Additionally, the panel includes multiple outlet options, accommodating various plug types, which enhances its versatility on job sites.

Durability is a hallmark of the Multiquip DCA-20SPX’s design. The generator is built with a sturdy steel frame and finished with weather-resistant coatings, enabling it to withstand the rigors of outdoor usage in challenging conditions. Its integrated handling features, such as fork pockets and lifting eyes, also facilitate easy transport and setup.

For user safety, the DCA-20SPX is equipped with essential protection features. It includes low oil shutdown, overload protection, and thermal shutdown, which collectively safeguard the generator from potential damage, ensuring long operational life and reliability.

Overall, the Multiquip DCA-20SPX excels in providing reliable energy solutions for various applications, adorned with advanced technologies, user-friendly features, and a robust build. Whether for construction, emergency power supply, or remote events, it stands as a trusted ally for those who require efficient and dependable power on demand.