DCA-45SSIU3 (60 Hz) — RULES FOR SAFE OPERATION

Maintenance Safety

The electrical voltage required to operate the generator can cause severe injury or even death through physical contact with live circuits. Turn all circuit breakers OFF before performing maintenance on the generator.

NEVER lubricate components or attempt service on a running machine.

ALWAYS disconnect the NEGATIVE battery terminal before performing service on the generator.

Follow all Battery Safety Guidelines listed in this manual when handling or servicing the generator.

ALWAYS allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts.

ALWAYS service air cleaner frequently to prevent engine malfunction.

WARNING - BURN HAZARDS

To prevent burns, DO NOT touch or open any of the below mentioned components while the engine is

running or immediately after operations. Always allow sufficient time for the engine and generator to cool before performing maintenance.

Radiator Cap - Removing the radiator cap while the engine is hot will result in high pressurized, boiling water to gush out of the radiator, causing severe scalding to any persons in the general area of the generator.

Coolant Drain Plug - Removing the coolant drain plug while the engine is hot will result in hot coolant gushing out of the coolant drain plug, therefore causing severe scalding to any persons in the general area of the generator.

Engine Oil Drain Plug - Removing the engine oil drain plug while the engine is hot will result in hot oil gushing out of the oil drain plug, therefore causing severe scalding to any persons in the general area of the generator.

Battery Safety

Use the following guidelines when handling the battery:

The battery contains acids that can cause injury to the eyes and skin. To avoid eye irritation, always wear safety glasses.

Use well insulated gloves when picking up the battery.

DANGER - EXPLOSION HAZARDS

The risk of an explosion exists when performing service on the battery. To avoid severe injury or DEATH:

DO NOT drop the battery.There is the possibility of risk that the battery may explode.

DO NOT expose the battery to open flames, sparks, cigarettes

etc.The battery contains combustible gases and liquids. If these gases and liquids come in contact with a flame or spark, an explosion could occur.

ALWAYS keep the battery charged. If the battery is not charged a buildup of combustible gas will occur.

ALWAYS keep battery charging and cables in good working condition. Repair or replace all worn cables.

ALWAYS recharge the battery in an vented air environment, to avoid risk of a dangerous concentration of combustible gases.

In case the battery liquid (dilute sulfuric acid) comes in contact with clothing or skin, rinse skin or clothing immediately with plenty of water.

In case the battery liquid (dilute sulfuric acid) comes in contact with your EYES, rinse eyes immediately with plenty of water and contact the nearest doctor or hospital to seek medical attention.

PAGE 12 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV. #0 (11/30/05)

Page 12
Image 12
Multiquip DCA-45SSIU3 operation manual Maintenance Safety, Battery Safety

DCA-45SSIU3 specifications

The Multiquip DCA-45SSIU3 is a robust and versatile diesel generator designed to provide reliable power for various applications, making it an essential piece of equipment for construction sites, events, and emergency backup. This generator is renowned for its efficiency, durability, and user-friendly design, catering to a wide range of power needs while ensuring optimal performance.

One of the standout features of the DCA-45SSIU3 is its powerful 45 kVA output. This generator is powered by a reliable and fuel-efficient Yanmar diesel engine, which not only delivers consistent power but also ensures lower emissions, making it an environmentally friendly choice for power generation. With its high fuel efficiency, operators can expect longer run times between refuels, reducing downtime and increasing productivity on the job site.

The DCA-45SSIU3 boasts a compact and mobile design, equipped with a durable steel frame and a weather-resistant enclosure. This ensures that the generator can withstand harsh outdoor conditions while providing easy access for maintenance and operation. Its built-in forklift channels and lifting eyes enhance its portability, allowing for simple relocation to different job sites.

This generator is equipped with advanced technologies that enhance its performance and safety. The intuitive control panel features easy-to-read gauges and indicators for monitoring performance. Users can quickly access essential functions, including start/stop controls and circuit breaker protections, which safeguard the generator from overloads. Additionally, its automatic voltage regulation delivers stable power, ensuring that sensitive electronic equipment runs smoothly without risk of damage.

The DCA-45SSIU3 also includes a fuel tank designed for extended operation, with a capacity that provides significant hours of runtime. This feature is complemented by an efficient cooling system that maintains optimal engine temperatures, ensuring reliability even during prolonged usage.

In summary, the Multiquip DCA-45SSIU3 is a powerful and dependable generator that meets the demands of diverse applications. Its robust design, combined with advanced features and efficiency, makes it an ideal choice for contractors, event planners, and anyone needing reliable backup power. With a reputation for performance and longevity, this generator stands out in the competitive market of portable power solutions.