Multiquip DCA-800SSK operation manual Caution -Trailer Fueltank, Refilling Procedures, refueling

Models: DCA-800SSK

1 120
Download 120 pages 57.25 Kb
Page 41
Image 41
CAUTION -TRAILER FUELTANK

DCA-800SSKPRE-SETUP

CAUTION -TRAILER FUELTANK

ALWAYS! fill trailer tank first with #2 diesel fuel, before filling secondary internal tank.

Figure 32. Skid Type Fuel Tank System

Refilling Procedures

WARNING - RESPIRATORY HAZARDS

Diesel fuel and its vapors are dangerous to your health and the surrounding environment. Avoid skin contact and/or inhaling fumes.

1.Level Tanks – make sure fuel cells are level with the ground. Failure to do so will cause fuel to spill from the tank before reaching full capacity. See Figure 33.

CAUTION - REFUELINGTHE GENERATOR

ALWAYS place trailer on firm level ground before refueling to prevent spilling and maximize the amount of fuel that can be pumped into the tank.

Figure 33. Only Fill on Level Ground

2.Trailer Fuel Tank First – The trailer fuel tank is the primary fuel tank and holds a larger capacity of fuel. The fuel in the trailer will be filtered and sent to the engine. ALWAYS fill trailer fuel tank (Figure 34) first.

Figure 34. Fuel Tank Filling Order

NOTE

ONLY! use #2 diesel fuel when

refueling.

 

Fuel from the secondary inner

NOTE tank will eventually drain into the primary trailer tank.

DCA-800SSK (STD) — OPERATION AND PARTS MANUAL — REV. #4 (06/03/10) — PAGE 41