Battery

This unit is of negative ground DO NOT connect in reverse. Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level are not properly maintained. Add only distilled water when replenishment is necessary.

DO NOT over fill. Check to see whether the battery cables are loose. Poor contact may result in poor starting or malfunctions. Always keep the terminals firmly tightened. Coating the terminals with an approved battery terminal treatment compound. Replace battery with only recommended type battery.

The battery is sufficiently charged if the specific gravity of the battery fluid is 1.28 (at 68° F). If the specific gravity should fall to 1.245 or lower, it indicates that the battery is dead and needs to be recharged or replaced.

Battery Cable Installation

ALWAYS be sure the battery cables (Figure 40) are properly connected to the battery terminals as shown below. The RED cable is connected to the positive terminal of the battery, and the BLACK cable is connected to the negative terminal of the battery.

CAUTION - BATTERY SERVICING SAFETY

ALWAYS disconnect the negative terminal FIRST and reconnect negative terminal LAST.

Figure 40. Battery Connections

DCA-800SSK— PRE-SETUP

When connecting battery do the following:

1.NEVER connect the battery cables to the battery terminals when the ignition switch is in either the Pre- Heat, RUN, or START position. ALWAYS make sure that the ignition switch is in the STOP position when connecting the battery.

2.Place a small amount of battery terminal treatment compound around both battery terminals.This will ensure a good connection and will help prevent corrosion around the battery terminals.

If the battery cable is connected incorrectly, electrical damage to the

NOTE generator will occur. Pay close attention to the polarity of the battery when connecting the battery.

CAUTION - BATTERY SERVICING SAFETY

Inadequate battery connections may cause poor starting of the generator, and create other malfunctions.

Alternator

The polarity of the alternator is negative grounding type. When an inverted circuit connection takes place, the circuit will be in short circuit instantaneously resulting the alternator failure.

DO NOT put water directly on the alternator. Entry of water into the alternator leads an electrolyte corrosion causing an alternator failure.

Before charging the battery with an external electric source, be sure to disconnect the battery cables.

Wiring

Inspect the entire generator for bad or worn electrical wiring or connections. If any wiring or connections are exposed (insulation missing) replace wiring immediately.

Piping and Hose Connection

Inspect all piping, oil hose, and fuel hose connections for wear and tightness.Tighten all hose clamps and check hoses for leaks.

If any hose (fuel or oil) lines are defective replace them immediately.

PAGE 44 — DCA-800SSK (STD) — OPERATION AND PARTS MANUAL — REV. #4 (06/03/10)

Page 44
Image 44
Multiquip DCA-800SSK operation manual Battery Cable Installation, Alternator, Wiring, Piping and Hose Connection

DCA-800SSK specifications

The Multiquip DCA-800SSK is a versatile and powerful generator designed for both commercial and residential applications. Renowned for its reliability and performance, this model is ideal for construction sites, events, and emergency power needs. One of its standout features is the robust 8000-watt output, which makes it suitable for running heavy-duty equipment, tools, and multiple appliances simultaneously.

At the heart of the DCA-800SSK is a reliable Honda engine, renowned for its durability and efficiency. This 4-stroke, air-cooled engine not only provides exceptional power but also boasts lower emissions, making it an environmentally friendly choice. The generator’s fuel tank capacity supports extended run times, ensuring that users can rely on it for prolonged periods without frequent refueling interruptions.

In terms of design, the Multiquip DCA-800SSK has a compact and sturdy frame that allows for easy transport and setup. With its rugged wheels and ergonomic handles, maneuvering the generator across job sites or in emergency situations is a breeze. Additionally, this model is equipped with an electric start feature, providing user convenience and saving time in critical situations.

The DCA-800SSK incorporates advanced technologies such as automatic voltage regulation (AVR), which ensures stable power delivery. This feature is crucial for protecting sensitive electronic devices from voltage fluctuations, making the generator suitable for a variety of applications, including powering computers, medical equipment, and other electronics.

Safety is also prioritized in the design of the DCA-800SSK. It comes with features like low-oil shutoff and overload protection, which prevent damage to both the generator and connected equipment.

With a noise level rated at a manageable decibel level, this generator is suitable for use in noise-sensitive environments. Overall, the Multiquip DCA-800SSK stands out for its combination of power, efficiency, and user-friendly features, making it a reliable choice for anyone in need of backup or portable power solutions. The brand’s reputation for quality and performance adds a layer of trust for users seeking dependable power sources in various settings.