DCA-125USJ — SAFETY INFORMATION

FUEL SAFETY

DANGER

„DO NOT start the engine near spilled fuel or combustible fluids. Diesel fuel is extremely flammable and its vapors can cause an explosion if ignited.

„ALWAYS refuel in a well-ventilated area, away from sparks and open flames.

„ALWAYS use extreme caution when working with flammable liquids.

„DO NOT fill the fuel tank while the engine is running or hot.

„DO NOT overfill tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system.

„Store fuel in appropriate containers, in well-ventilated areas and away from sparks and flames.

„NEVER use fuel as a cleaning agent.

„DO NOT smoke around or near the equipment. Fire or explosion could result

from fuel vapors or if fuel is spilled on a hot engine.

TOWING SAFETY

CAUTION

„Check with your local county or state safety

towing regulations, in addition to meeting

Department of Transportation (DOT) SafetyTowing Regulations, before towing your generator.

„Refer to MQ Power trailer manual for additional safety information.

„In order to reduce the possibility of an accident while transporting the generator on public roads, ALWAYS make sure the trailer that supports the generator and the towing vehicle are mechanically sound and in good operating condition.

„ALWAYS shutdown engine before transporting

„Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer “gross vehicle weight rating.”

„ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains, etc.

„Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

„ALWAYS make sure the trailer is equipped with a safety chain.

„ALWAYS properly attach trailer’s safety chains to towing vehicle.

„ALWAYS make sure the vehicle and trailer directional, backup, brake and trailer lights are connected and working properly.

„DOT Requirements include the following:

s #ONNECT AND TEST ELECTRIC BRAKE OPERATION

s 3ECURE PORTABLE POWER CABLES IN CABLE TRAY WITH TIE wraps.

„The maximum speed for highway towing is 55 MPH unless posted otherwise.Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

„Avoid sudden stops and starts.This can cause skidding, or jack-knifing. Smooth, gradual starts and stops will improve towing.

„Avoid sharp turns to prevent rolling.

„Trailer should be adjusted to a level position at all times when towing.

„Raise and lock trailer wheel stand in up position when towing.

„Place chock blocks underneath wheel to prevent rolling while parked.

„Place support blocks underneath the trailer’s bumper to prevent tipping while parked.

„Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

DCA-125USJ — OPERATION AND PARTS MANUAL — REV. #2 (01/27/11) — PAGE 11

Page 11
Image 11
Multiquip DCA125USJ „ Never use fuel as a cleaning agent, From fuel vapors or if fuel is spilled on a hot engine

DCA125USJ specifications

The Multiquip DCA125USJ is a robust, high-performance generator designed to meet the diverse needs of various industries, including construction, events, and emergency backup. This generator boasts a compact size and impressive output, making it a reliable choice for both temporary and permanent power solutions.

At the heart of the DCA125USJ is a powerful diesel engine, providing an impressive 125 kVA output. This engine is engineered for efficiency, ensuring that the generator can continuously deliver reliable power while maintaining low operational costs. The generator operates at low RPM, which not only extends the engine's lifespan but also reduces noise levels, making it ideal for urban environments and sensitive locations.

One of the standout features of the DCA125USJ is its advanced electronic control system. This technology allows for seamless monitoring and management of the generator's performance, ensuring optimal operation. The control panel is user-friendly, offering real-time data on voltage, frequency, and operating hours, which simplifies maintenance and troubleshooting.

The DCA125USJ is equipped with a sturdy, weather-resistant enclosure that protects it from the elements, making it suitable for outdoor applications. This enclosure also contributes to noise reduction, ensuring quieter operation compared to traditional generators. Additionally, its compact design allows for easy transport and installation, making it a versatile option for various job sites.

Safety is a top priority in the design of the DCA125USJ. It features multiple safety mechanisms, such as an automatic shut-off system that activates in the event of low oil pressure or overheating, protecting the generator and prolonging its operational life.

Moreover, the DCA125USJ is compliant with rigorous emissions standards, making it an environmentally responsible choice. It offers options for multiple voltage outputs, which adds to its adaptability for different applications, from powering heavy machinery to providing electricity for small tools.

In summary, the Multiquip DCA125USJ stands out for its powerful diesel engine, state-of-the-art electronic controls, robust construction, and focus on safety and efficiency. Whether used in construction, outdoor events, or as a backup power source, the DCA125USJ is engineered to deliver reliable performance in a user-friendly package. This makes it a top contender for anyone needing dependable generator capabilities.