GA-3.6RZ2 — OPERATING INSTRUCTIONS

Before Starting

1.Be sure to disconnect the electrical load and switch the main circuit breaker to the “OFF” position prior to starting the engine.

2.Never start the engine with the main circuit breaker “ON”.

3.Check the lubricating oil level prior to starting the engine. Make sure the generator is level. The oil level must be maintained between two notches on the dipstick.

4.When there is not enough lubricating oil, fill the crankcase with high grade motor oil. Use a high quality detergent oil classified SC, SD or SE. (See Table 3 on page 13)

CAUTION:

λNEVER start the engine when the oil level is below the lower mark on the dipstick.

λCheck the fuel level on the fuel gauge. When fuel is low, fill the fuel tank with clean fresh unleaded automotive gasoline.

λIf gasoline spillage occurs, completely wipe up the spilled gasoline.

Starting

1.Open the fuel cock located below the fuel tank. The fuel starts to flow when the fuel cock lever is turned downward.

2.Place the idle control switch in the “ON” (up) position.

3.Close the choke. Adjust the opening of the choke valve according to operating conditions. When the engine is warm or the air temperature is high, close the choke valve halfway or open it all the way.

4.Confirm that the main circuit breaker on the generator control box is “OFF”.

5.Set the operation switch to the “ON” position and grasp the starting knob and slowly pull it out. The resistance becomes hardest at a certain position, corresponding to the compression point. Rewind the rope a little from that point and pull out sharply.

6.If the engine fails to start, repeat the procedure.

CAUTION: λ DO NOT pull the starter rope all the way to the end.

λDO NOT release the starter knob after pulling. Allow it to rewind as soon as

Warm up

1.When the engine starts, open the choke slowly.

2.Run the engine at low speed for 3 minutes without load until the engine warms up.

3.Turn the idle control switch to the "OFF" (down) position and check the voltage by referring to the voltmeter on the control box.

CAUTION:

DO NOT change the engine speed control lever which has been set at the factory prior to shipping.

1.Check the generator for abnormal noise and smells.Then connect the load to the receptacles of the generator.

2.Switch the main circuit breaker to the “ON” position and turn the idle control switch to the “ON” (down) position for normal (load) engine operation.

Operation

Check the voltage by referring to the voltmeter on the control box. When the voltmeter indicates 120 volts, 120 volts from the 120V receptacle can be obtained. Refer to Figure 1, Controls and Indicators, item 5 on page 10.

Stopping the Engine

CAUTION:

NEVER stop the engine suddenly while running at high speeds.

1.Remove the load from the generator. Place the circuit breaker in the “OFF” position. Refer to Figure 1, item 2 on page 10. Run the engine (no-load) with the idle control switch set to the ON position for three to five minutes, then stop the engine.

2.Turn the START/STOP switch to the “STOP” position.

3.Close the fuel cock.

PAGE 16 — GA-3.6RZ2 A.C. GENERATOR— PARTS & OPERATION MANUAL — REV. #2 (03/05/01)

Page 16
Image 16
Multiquip GA-3.6RZ2 operation manual Before Starting, Warm up, Operation, Stopping the Engine

GA-3.6RZ2 specifications

The Multiquip GA-3.6RZ2 is a highly versatile and robust generator that caters to various power needs, making it a reliable choice for construction sites, outdoor events, and emergency backup. This generator stands out for its impressive combination of power output, portability, and durability, ensuring that users have access to an uninterrupted power supply when required.

One of the key features of the GA-3.6RZ2 is its powerful engine. The generator is equipped with a reliable and fuel-efficient engine that delivers a maximum output of 3600 watts, making it suitable for running multiple tools and equipment simultaneously. This allows for efficient operation and strong performance in demanding environments. The engine also boasts a low noise level, making it suitable for use in noise-sensitive areas.

Portability is another significant aspect of the GA-3.6RZ2. Designed with a sturdy frame and integrated wheels, this generator is easy to move and transport, allowing users to take it wherever power is needed. Its compact design aids in saving space, whether it is being stored or deployed for use.

In terms of technology, the GA-3.6RZ2 incorporates advanced features that enhance its usability and reliability. It comes with intuitive controls that make it user-friendly, even for those who may not have extensive experience with generators. Additionally, the generator includes a built-in fuel gauge that allows users to monitor fuel levels easily, preventing unexpected shut-downs.

Durability is highlighted by the GA-3.6RZ2's rugged design, which is built to withstand harsh conditions often encountered on job sites. Its heavy-duty frame and high-quality components ensure that it can handle demanding tasks while providing long-lasting performance. The generator is also equipped with safety features such as circuit breakers that protect against overload and ensure safe operation.

The GA-3.6RZ2 functions efficiently in various applications, from powering electrical tools on construction sites to supplying backup power for critical home appliances during outages. With its combination of power, portability, user-friendly features, and durable construction, the Multiquip GA-3.6RZ2 is an ideal choice for users seeking reliability and performance in diverse power applications. In summary, this generator exemplifies Multiquip’s commitment to providing high-quality, dependable equipment for both professionals and casual users alike.