GA-3.6RZ2 —TROUBLESHOOTING (GENERATOR)

Practically all generator breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, please take a remedial action following the

diagnosis based on the Generator Troubleshooting (Table 5) information shown below and on the preceding page. If the problem cannot be remedied, please leave the unit just as it is and consult our company's business office or service plant.

TABLE 5. GENERATOR TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

Low voltage

Engine speed too low?

Raise engine speed to rated RPM.

 

 

 

 

AC voltmeter not working?

Replace AC voltmeter.

 

 

 

 

Control box internal wiring

Check control box wiring.

 

malfunction?

 

 

 

 

 

Defective ignition coil?

Check red and green ignition wires. Replace ignition wires if

Low voltage. Engine speed

 

necessary.

normal 3650 RPM (unloaded),

 

 

Rotor winding malfunction?

Check or replace rotor.

2500 RPM (idle)

 

 

 

 

Stator winding malfunction?

Check or replace stator.

 

 

 

 

Breaker malfunction?

Check or replace CB1.

 

 

 

 

Full power switch malfunction?

Check full power switch and full power switch circuit.

 

 

 

Voltage output too high.

Engine speed too high?

Lower engine speed to rated RPM.

 

 

 

Voltage output too high. Engine

Control box internal wiring

Check control box wiring.

speed normal 3650 RPM

malfunction

 

(unloaded), 2500 RPM (idle)

 

 

 

 

 

Circuit breaker will not turn on

Defective circuit breaker?

Replace circuit breaker.

"NO LOAD"

 

 

 

 

 

Circuit breaker will turn on

Overload?

Reduce load or replace breaker.

 

 

"LOADED" but trips immediately.

Load circuit is shorted?

Check load circuit for short.

 

 

 

 

Does not accelerate from low to

Stuck solenoid?

Check solenoid.

 

 

high "NO LOAD"

Bad Idle control switch?

Check or replace idle control switch.

 

 

 

 

 

Idle control switch malfunction?

Check or replace idle control switch.

Does not accelerate from low to

 

 

Idle control device malfunction?

Check or replace idle control device.

high "LOAD ACTIVE"

 

 

 

Control box interal wiring

Check control box wiring.

 

defective?

 

 

 

 

PAGE 22 — GA-3.6RZ2 A.C. GENERATOR— PARTS & OPERATION MANUAL — REV. #2 (03/05/01)

Page 22
Image 22
Multiquip GA-3.6RZ2 -TROUBLESHOOTING Generator, Generator Troubleshooting Symptom Possible Problem Solution

GA-3.6RZ2 specifications

The Multiquip GA-3.6RZ2 is a highly versatile and robust generator that caters to various power needs, making it a reliable choice for construction sites, outdoor events, and emergency backup. This generator stands out for its impressive combination of power output, portability, and durability, ensuring that users have access to an uninterrupted power supply when required.

One of the key features of the GA-3.6RZ2 is its powerful engine. The generator is equipped with a reliable and fuel-efficient engine that delivers a maximum output of 3600 watts, making it suitable for running multiple tools and equipment simultaneously. This allows for efficient operation and strong performance in demanding environments. The engine also boasts a low noise level, making it suitable for use in noise-sensitive areas.

Portability is another significant aspect of the GA-3.6RZ2. Designed with a sturdy frame and integrated wheels, this generator is easy to move and transport, allowing users to take it wherever power is needed. Its compact design aids in saving space, whether it is being stored or deployed for use.

In terms of technology, the GA-3.6RZ2 incorporates advanced features that enhance its usability and reliability. It comes with intuitive controls that make it user-friendly, even for those who may not have extensive experience with generators. Additionally, the generator includes a built-in fuel gauge that allows users to monitor fuel levels easily, preventing unexpected shut-downs.

Durability is highlighted by the GA-3.6RZ2's rugged design, which is built to withstand harsh conditions often encountered on job sites. Its heavy-duty frame and high-quality components ensure that it can handle demanding tasks while providing long-lasting performance. The generator is also equipped with safety features such as circuit breakers that protect against overload and ensure safe operation.

The GA-3.6RZ2 functions efficiently in various applications, from powering electrical tools on construction sites to supplying backup power for critical home appliances during outages. With its combination of power, portability, user-friendly features, and durable construction, the Multiquip GA-3.6RZ2 is an ideal choice for users seeking reliability and performance in diverse power applications. In summary, this generator exemplifies Multiquip’s commitment to providing high-quality, dependable equipment for both professionals and casual users alike.