GA-3.6RZ2 —TROUBLESHOOTING (ENGINE)

Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, please take a remedial action following the

diagnosis based on the Engine Troubleshooting (Table 4) information shown below and on the proceeding page. If the problem cannot be remedied, please leave the unit just as it is and consult our company's business office or service plant.

TABLE 4. ENGINE TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

Inspect carburetor to see if fuel

Check fuel line

 

is reaching it?

 

 

 

 

 

No Fuel?

Add Fuel

 

 

 

 

Water in fuel tank?

Flush or replace fuel tank.

 

 

 

 

Fuel filter clogged?

Replace fuel filter

 

 

 

 

Stuck carburetor?

Check float mechanism.

Poor starting

 

 

Spark plug is red?

Spark plug is fouled. Check tranistor ignition unit.

 

 

 

 

Spark plug is blue-white?

Insufficient compression, injected air leaking. Carburetor jets are

 

clogged (overflow).

 

 

 

 

 

 

No spark present at tip of spark

Tranistor ignition unit broken, high voltage cord cracked or broken.

 

plug?

Start/Stop switch broken. Replace spark plug if fouled.

 

 

 

 

No oil?

Add oil as required.

 

 

 

 

Oil pressure alarm lamp blinks

Check Automatic shutdown circuit "oil sensor".

 

upon starting?

 

 

 

 

 

 

Engine will not turn over?

Replace cylinder and piston and if necessary axel joint.

 

 

 

 

Cylinder head connecting bolts

Tighten cylinder head connecting bolts.

 

loose?

 

 

 

 

 

Insufficient power output "no

Cylinder head gasket damaged?

Replace cylinder head gasket.

compression"

 

 

Malfunction of valve seat?

Re-seat valves.

 

 

 

 

 

Spark plug is loose?

Replace spark plug.

 

 

 

 

Worn piston rings?

Replace piston rings.

 

 

 

 

Malfunction in air-cleaner system,

Clean or replace air filter.

 

air filter clogged?

 

 

 

 

 

 

Air leaking in from interface

Tighten bolts between carburetor and cylinder head. Replace

Insufficient power output

between carburetor and cylinder

cylinder head gasket.

"compression"

head?

 

 

 

 

 

 

Clean or replace fuel filter.

 

Malfunction in fuel system?

Clean or replace carburetor.

 

 

Check carburetor float.

 

 

 

PAGE 20 — GA-3.6RZ2 A.C. GENERATOR— PARTS & OPERATION MANUAL — REV. #2 (03/05/01)

Page 20
Image 20
Multiquip operation manual GA-3.6RZ2 -TROUBLESHOOTING Engine

GA-3.6RZ2 specifications

The Multiquip GA-3.6RZ2 is a highly versatile and robust generator that caters to various power needs, making it a reliable choice for construction sites, outdoor events, and emergency backup. This generator stands out for its impressive combination of power output, portability, and durability, ensuring that users have access to an uninterrupted power supply when required.

One of the key features of the GA-3.6RZ2 is its powerful engine. The generator is equipped with a reliable and fuel-efficient engine that delivers a maximum output of 3600 watts, making it suitable for running multiple tools and equipment simultaneously. This allows for efficient operation and strong performance in demanding environments. The engine also boasts a low noise level, making it suitable for use in noise-sensitive areas.

Portability is another significant aspect of the GA-3.6RZ2. Designed with a sturdy frame and integrated wheels, this generator is easy to move and transport, allowing users to take it wherever power is needed. Its compact design aids in saving space, whether it is being stored or deployed for use.

In terms of technology, the GA-3.6RZ2 incorporates advanced features that enhance its usability and reliability. It comes with intuitive controls that make it user-friendly, even for those who may not have extensive experience with generators. Additionally, the generator includes a built-in fuel gauge that allows users to monitor fuel levels easily, preventing unexpected shut-downs.

Durability is highlighted by the GA-3.6RZ2's rugged design, which is built to withstand harsh conditions often encountered on job sites. Its heavy-duty frame and high-quality components ensure that it can handle demanding tasks while providing long-lasting performance. The generator is also equipped with safety features such as circuit breakers that protect against overload and ensure safe operation.

The GA-3.6RZ2 functions efficiently in various applications, from powering electrical tools on construction sites to supplying backup power for critical home appliances during outages. With its combination of power, portability, user-friendly features, and durable construction, the Multiquip GA-3.6RZ2 is an ideal choice for users seeking reliability and performance in diverse power applications. In summary, this generator exemplifies Multiquip’s commitment to providing high-quality, dependable equipment for both professionals and casual users alike.