Multiquip manual GA-6RE/GA-6REA- CONTROLS AND INDICATORS, When the full power switch is in the

Models: GA-6RE GA-6REA

1 76
Download 76 pages 7.39 Kb
Page 18
Image 18
GA-6RE/GA-6REA — CONTROLS AND INDICATORS

GA-6RE/GA-6REA — CONTROLS AND INDICATORS

Figure 3B. Generator Components

13. Full Power Switch – The generators are provided with a full power switch. Figures 3C and 3D show simplified wiring diagrams of the dual voltage system.

When the full power switch is in the 120 volt (up) position, you can access the full rated power of the generator at 120 volts from the GFCI duplex receptacle and the120V twist-lock receptacle, or a combination of both receptacles as long as the total load does not exceed the generating set capacity.

When the switch is in the 240 volt (down) position, you can acess half of the rated power of the generating set at 120 volts from the GFCI duplex receptacle and up to half of the rated power of the set at 120 volts from 120V twist-lock receptacle; or full rated power of the set at 240 volts from the 240V twist-lock receptacle.

Figure 3C. 120V Full Power Switch Simplified Diagram (Up Position)

When the full power switch is in the

NOTE 120V position, the 240V twist-lock receptacle cannot be used.

Figure 3D. 120/240V Full Power Switch Simplified Diagram (Down Position)

PAGE 18 — GA-6RE/GA-6REA A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (06/06/05)

Page 18
Image 18