GA-6RE/GA-6REA — GENERATOR OPERATION/SHUTDOWN
5.Read the voltmeter on the front panel of the generators (Figure 22) and verify that 240 VAC is present at the 240V
Stopping the Engine
1.Place the main circuit breaker (Figure 23) in the OFF position.
Figure 23. Main Circuit Breakers (Off)
2.Place the idle control switch (Figure 24) in the OFF position.
Figure 24. Idle Control Switch (Off)
3.Let the engine run at idle with no load for
4.To
Figure 22. 60 Hz Output Receptacles
When the full power switch is in the 240
NOTE volt (down) position, you can take up to half of the rated power of the generating set at 120 volts from the GFCI duplex
receptacle and up to half of the rated power of the set at 120 volts from the 120V
When using a combination of dual
NOTE receptacles, total load should not exceed the rated capacity of the generator.
Figure 25. Generator On/Off Switch (Off)
5.Place the engine fuel valve lever (Figure 26) to the "OFF" position.”
Connecting the Load | Figure 26. Engine Fuel Valve Lever (OFF Position) |
|
1.If small wattage power tools are required, connect them 6. Remove the all loads from the generator. to the 60 Hz output receptacles at this time.