Multiquip GA-6RE/GA-6REA- MAINTENANCE ENGINE, Engine Maintenance Schedule, First, Every, Year

Models: GA-6RE GA-6REA

1 76
Download 76 pages 7.39 Kb
Page 29
Image 29
GA-6RE/GA-6REA — MAINTENANCE (ENGINE)

GA-6RE/GA-6REA — MAINTENANCE (ENGINE)

Use Table 6 as a general maintenance guideline when servicing your engine. For more detail engine maintenance information, refer to the engine owner's manual supplied with your engine.

Table 6. Engine Maintenance Schedule

 

 

 

FIRST

 

EVERY

EVERY

EVERY

EVERY

DESCRIPTION (3)
OPERATION
BEFORE
MONTH

 

3 MONTHS6 MONTHS
YEAR
2 YEARS

OR

 

OR

OR

OR

OR

 

 

 

 

 

 

 

10 HRS.

 

25 HRS.50 HRS.100 HRS.200 HRS.

 

 

 

 

 

 

 

 

 

Engine Oil

CHECK

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHANGE

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Cleaner

CHECK

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHANGE

 

 

 

X (1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All Nuts & Bolts

Re-tighten If

X

 

 

 

 

 

 

Necessary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Spark Plug

CHECK-CLEAN

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

REPLACE

 

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Fins

CHECK

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Spark Arrester

CLEAN

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

Fuel Tank

CLEAN

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

Fuel Filter

CHECK

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

Idle Speed

CHECK-ADJUST

 

 

 

 

 

X (2)

 

 

 

 

 

 

 

 

 

 

Valve Clearance

CHECK-ADJUST

 

 

 

 

 

 

X (2)

 

 

 

 

 

 

 

 

 

Fuel lines

CHECK

 

 

Every 2 years (replace if necessary) (2)

 

 

 

 

 

 

 

 

 

 

(1)Service more frequently when used in DUSTY areas.

(2)These items should be serviced by your service dealer, unless you have the proper tools and are mechanically proficient. Refer to the HONDA Shop Manual for service procedures.

(3)For commercial use, log hours of operation to determine proper maintenance intervals.

GA-6RE/GA-6REA A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (06/06/05) — PAGE 29