GB12BW/BS/BP LIGHTING SYSTEM — MAINTENANCE

Filter Replacement

WARNING - HOT SURFACE (LAMP FRAME)

DO NOT replace filter immediately, allow a sufficient amount of time for the lamp assembly to cool down before changing filter.

5.Install a new filter over the brace as shown in Figure 44. Be sure to align the cut of the filter over the brace.

BRACE

FILTER

1.Remove the balloon as described in the "Removing the Lamp/Balloon" section.

2.Disconnect the lamp power cable.

3.Rotate the balloon/lamp base assembly so that the filter is facing upwards. See Figure 42.

BALLOON/LAMP

Figure 42. Balloon/Lamp Placement

CUT

Figure 44. Filter Placement

CAUTION - FILTER ALIGNMENT

When placing the filter element, always align the cut of the filter on top of the brace. This will keep the filter from being dislodged and getting damaged.

4.Using a small phillips-head screwdriver, remove the three screws/washers that secure the air plate to the lamp base (Figure 43). Remove air plate and filter.

6.Using a small phillips-head screwdriver, reinstall the three screws/washers to secure the air plate to the lamp base (Figure 45).

 

SCREW

 

 

 

AND

 

SCREW

AIR

WASHER

FILTER

PLATE

 

AND

 

 

 

 

WASHER

 

 

 

LAMP

BASE

Figure 43. Filter Removal

Figure 45. Filter/Plate Install

PAGE 26 — GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08)

Page 26
Image 26
Multiquip manual GB12BW/BS/BP Lighting System Maintenance, Filter Replacement

GB12BW/BS/BP specifications

The Multiquip GB12BW/BS/BP is a versatile and powerful generator designed to meet diverse energy needs in various applications, from construction sites to outdoor events. Recognized for its reliability and efficiency, this generator series is popular among professionals and contractors seeking a robust power solution.

Key features of the GB12 series include its impressive output capabilities. The GB12BW, for instance, offers a continuous operation of 12 kW, making it suitable for powering multiple tools and equipment simultaneously. The machine operates with a three-phase or single-phase output, which adds versatility, catering to both larger power demands and smaller, localized needs.

One of the standout technologies within the GB12 lineup is its advanced noise reduction system. The generators are equipped with soundproof enclosures designed to minimize operational noise without sacrificing performance. This feature is particularly beneficial in noise-sensitive environments such as residential areas or during nighttime operations.

In terms of fuel efficiency, the GB12BW/BS/BP models are engineered with high-performance engines that ensure maximum runtime on a single tank of fuel. This efficiency is crucial for prolonged job sites where refueling may be inconvenient. Additionally, with lower fuel consumption rates, operators can reduce operational costs while maintaining productivity.

Durability is another hallmark of the GB12 series. Constructed with high-quality materials, these generators are built to withstand the rigors of heavy-duty use. The compact design allows for easy transportation, while the robust frame ensures stability during operation. This makes the GB12 ideal for both stationary and mobile applications.

User-friendly controls and features such as automatic voltage regulation make the GB12 series easy to operate. This technology ensures a steady power supply and protects connected equipment from voltage fluctuations, enhancing safety and equipment longevity.

Furthermore, the GB12 models come equipped with comprehensive safety features, including low oil shutdown and circuit breakers, which prevent damage and reduce the risk of accidents during operation.

In summary, the Multiquip GB12BW/BS/BP series offers a reliable, efficient, and durable power solution for various applications. With advanced technologies, enhanced fuel efficiency, and user-friendly features, it meets the demands of modern professionals seeking maximum productivity in their power generation needs.