GLOBUG GB12BW/BS/BP LIGHTING SYSTEM — SETUP (GB12BS)

Raising the Mast (GB12BS)

1.Before raising the mast, make sure the T-handle bolt lock (see Figure 26-O) is securely tightened. This will prevent the balloon/lamp assembly from falling off. In addition make sure that the lamp power cable is connected to the mating end of the power source cable.

2.Raise extension pole (see Figure 26-L) to desired height. Watch out for any overhead obstructions.

3.Using the supplied 19 mm wrench tighten extension clamp bolt (see Figure 26-Q) securely. Place wrench in a safe place where it will not get lost.

Applying Power (GB12BS)

1.If using a portable generator, start the generator as referenced in the "Start-up Section" of the supplied generator manual.

2.Once the generator has started, plug the AC power cord from the lamp into a GFCI receptacle on the generator.

3.If using a power source (Figure 31) other than a portable generator, plug the AC power cord from the lamp into a 120 VAC, 60 Hz receptacle that is protected by a at least a 15 amp circuit breaker.

DANGER - Overhead Obstructions

ALWAYS make sure the area above the lighting system is open and clear of overhead power lines and other obstructions. The mast can extend in

excess of 8 ft. (2.4 meters) depending on the type of equipment it is attached to.

POWER CABLE

RECEPTACLE

EXTERNAL

SINGLE-PHASE

(120 VAC)

POWER SOURCE

Contact with overhead power lines or other obstructions could result in equipment damage,

Serious Injury or Death!

DANGER - HIGHVOLTAGE POWER LINES

When raising mast, ALWAYS be on the lookout for overhead obstructions such as high voltage power lines.The possibility exists of electrocution,

even death! if the lighting system comes in contact with high voltage power lines.

Figure 31. 120 VAC Receptacle

4.Notice that the balloon envelope will begin to deploy as soon as power is applied.

5.The lamp should now be on. If the lamp is not on, check all connections and repeat steps 1, 2 and 3. If the lamp still does not come on, refer to the troubleshooting tables provided in the maintenance section of this manual.

6.The GB12BS lighting system is now ready for use.

Shutdown

1.If using a portable generator, shut-down the generator as referenced in the "Shutdown Section" of the supplied generator manual. ALWAYS place the main circuit breaker in the OFF position before turning off the generator.

2.If using a power source other than an AC generator, disconnect the lamp AC power cable from the power source. The balloon should begin to deflate.

3.Remove and store balloon assembly as referenced in the "storage" section of the GB12BW.

GLOBUG LIGHTING SYSTEM — OPERATION AND PARTS MANUAL — REV. #2 (11/03/08) — PAGE 23

Page 23
Image 23
Multiquip GB12BW/BS/BP manual Raising the Mast GB12BS, Applying Power GB12BS, GB12BS lighting system is now ready for use

GB12BW/BS/BP specifications

The Multiquip GB12BW/BS/BP is a versatile and powerful generator designed to meet diverse energy needs in various applications, from construction sites to outdoor events. Recognized for its reliability and efficiency, this generator series is popular among professionals and contractors seeking a robust power solution.

Key features of the GB12 series include its impressive output capabilities. The GB12BW, for instance, offers a continuous operation of 12 kW, making it suitable for powering multiple tools and equipment simultaneously. The machine operates with a three-phase or single-phase output, which adds versatility, catering to both larger power demands and smaller, localized needs.

One of the standout technologies within the GB12 lineup is its advanced noise reduction system. The generators are equipped with soundproof enclosures designed to minimize operational noise without sacrificing performance. This feature is particularly beneficial in noise-sensitive environments such as residential areas or during nighttime operations.

In terms of fuel efficiency, the GB12BW/BS/BP models are engineered with high-performance engines that ensure maximum runtime on a single tank of fuel. This efficiency is crucial for prolonged job sites where refueling may be inconvenient. Additionally, with lower fuel consumption rates, operators can reduce operational costs while maintaining productivity.

Durability is another hallmark of the GB12 series. Constructed with high-quality materials, these generators are built to withstand the rigors of heavy-duty use. The compact design allows for easy transportation, while the robust frame ensures stability during operation. This makes the GB12 ideal for both stationary and mobile applications.

User-friendly controls and features such as automatic voltage regulation make the GB12 series easy to operate. This technology ensures a steady power supply and protects connected equipment from voltage fluctuations, enhancing safety and equipment longevity.

Furthermore, the GB12 models come equipped with comprehensive safety features, including low oil shutdown and circuit breakers, which prevent damage and reduce the risk of accidents during operation.

In summary, the Multiquip GB12BW/BS/BP series offers a reliable, efficient, and durable power solution for various applications. With advanced technologies, enhanced fuel efficiency, and user-friendly features, it meets the demands of modern professionals seeking maximum productivity in their power generation needs.