| TROUBLESHOOTING |
|
|
|
|
|
|
|
|
|
| TABLE 8. ENGINE TROUBLESHOOTING (Continued) | |||
|
|
|
|
|
|
|
| SYMPTOM |
| POSSIBLE PROBLEM |
|
| SOLUTION |
|
|
|
|
|
|
|
| Operation not satisfactory |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Governor adjustment improper? |
| Adjust governor to correct lever. | |
|
|
|
|
|
|
|
|
|
| Governor spring defective? |
| Clean or replace ignition. | |
| Rotational speed fluctuates. |
|
|
|
|
|
| Fuel flow erratic? |
| Check fuel line. | |||
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| Air taken in through suction |
| Check suction line. | |
|
|
| line? |
|
|
|
|
|
|
|
|
|
|
| Recoil starter not working |
| Dust in rotating part? |
| Clean recoil starter assembly. | |
|
|
|
|
|
| |
| properly. |
| Spring spring failure? |
| Replace sprial spring. | |
|
|
|
| |||
|
|
|
|
|
| |
|
|
|
|
| ||
|
|
| TABLE 9. PUMP TROUBLESHOOTING | |||
|
|
|
|
|
| |
| SYMPTOM |
| POSSIBLE PROBLEM |
| SOLUTION | |
|
|
|
| |||
|
| Not enough priming water in the housing? | Add water to suction chamber. | |||
|
|
|
|
| ||
|
| Engine speed too low? |
| Increase throttle. | ||
|
|
|
|
| ||
|
| Strainner plugged? |
| Clean strainer. | ||
|
|
|
|
| ||
|
| Suction hose damaged? |
| Replace or repair hose, and clamps | ||
|
|
|
|
|
| |
|
|
| Air leak at suction port? |
| Check that fittings are tight and properly sealed. | |
|
|
|
| |||
| Pump does not take on water. | Pump is located too high above water line? | Move pump closer to water. | |||
|
| Debris collecting in pump housing? |
| Clean pump housing. | ||
|
|
|
|
| ||
|
|
| Water leaking out weep hole between pump and | Check condition of mechanical seal and gaskets, | ||
|
| engine? |
| between pump end and engine housing. | ||
|
|
|
|
|
|
|
|
| Valves not seated correctly? |
| Check that valves are seated correctly. Pour water in | ||
|
|
| in suction chamber to help seal valves. | |||
|
|
|
|
|
| |
|
|
|
|
| ||
|
| Pump does not prime correctly? |
| Check diaphragm for breaks or leaks. | ||
|
|
|
|
| ||
| Pump takes in water, little or no | Engine speed too low? |
| Increase throttle speed. | ||
|
|
|
|
|
| |
| discharge. | Suction strainer partially plugged? |
| Clean strainer. | ||
|
|
| ||||
|
|
|
|
|
| |
| Suction hose leaks at inlet. |
| Teflon Tape/Pipe Dope not used? |
| Apply teflon tape or pipe dope to NPT fittings. | |
|
|
|
|
|
| |
| Hose diameter is too large? |
| Use same diameter on suction/discharge ports. | |||
|
|
| ||||
|
|
|
|
| ||
| Discharge hose does not stay | Pressure too high? |
| Check pressure, add additional clamp. | ||
|
|
|
|
|
| |
| on coupling. | Hose kinked or end blocked? |
| Check hose. | ||
|
|
| ||||
|
|
|
|
|
|
|
PAGE 28 — MQD2H/3H DIAPHRAGM PUMPS — OPERATION AND PARTS MANUAL — REV. #6 (10/27/11)