SAFETY INFORMATION

PUMP SAFETY

DANGER

„ NEVER operate the equipment in an explosive atmosphere or near combustible materials.An explosion or fire could result causing severe bodily harm or even death.

„NEVERusepumpforswimmingpooldewateringapplications. This can result in electrical shock or electrocution.

WARNING

„Accidental starting can cause severe injury or death. ALWAYS place the ON/OFF switch in the OFF position.

„ DO NOT place hands or fingers inside pump when pump is running.

„NEVER disconnect any emergency or

safety devices. These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.

CAUTION

„DO NOT restrict the flow of the discharge hose as it may cause overheating.

„Be careful of discharge whipping under pressure.

NOTICE

„ALWAYS place the pump in an upright position on a platform before using.The platform will prevent the pump frowm burrowing itself on soft sand or mud.

„NEVER operate pump on its side.

„DO NOT allow up to freeze in water.

„NEVER leave an open pump chamber unattended.

„ALWAYS keep the machine in proper running condition.

„DO NOT attempt to thaw-out a frozen pump by using a torch or other source of flame. Application of heat in this manner may heat the oil in the seal cavity above the critical point, causing pump damage.

„DO NOT pump water greater than 104º F.

„DO NOT pump liquids containing acid or alkali.

„ALWAYS check strainer before pumping. Make sure strainer is not clogged. Remove any large objects, dirt or debris from the strainer to prevent clogging.

„ALWAYS use a large basket strainer when pumping water that contains large debris.

„ALWAYS flush pump (clean) after use when pumping water concentrated with heavy debris. It is very important to always flush the pump before turning it off to prevent clogging.

„Fix damage to machine and replace any broken parts immediately.

„ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel.

„NEVER lubricate components or attempt service on a running machine.

„ALWAYS allow the machine a proper amount of time to cool before servicing.

„Keep machine in proper running condition.

ELECTRICAL SAFETY

DANGER

„ The electrical voltage required to operate pump can cause severe injury or even death through physical contact with live circuits. ALWAYS disconnect electrical power from pump before performing maintenance on pump.

NOTICE

„ALWAYS make certain that the voltage supplied to the pump is correct. Always read the pump’s nameplate to determine what the power requirements are.

PAGE 8 — MQD2H/3H DIAPHRAGM PUMPS — OPERATION AND PARTS MANUAL — REV. #6 (10/27/11)

Page 8
Image 8
Multiquip MQD2H manual Pump Safety

MQD2H specifications

The Multiquip MQD2H is a versatile and robust diesel-powered generator designed to cater to a wide range of applications, making it a staple for construction sites, emergency backup, and outdoor events. Engineered with advanced technologies, this generator is built to deliver reliable power and withstand challenging environments.

At the heart of the MQD2H is a powerful, fuel-efficient diesel engine that ensures long operational hours with minimal downtime. This efficiency is crucial for projects requiring continuous power supply. Equipped with a large fuel tank, the MQD2H can operate for extended periods without the need for frequent refueling, enhancing productivity on the job site.

One of the standout features of the MQD2H is its robust construction. The generator is housed in a durable frame that protects it from physical damage and harsh weather conditions. Its compact design allows for easy transportation and maneuverability, making it ideal for various locations. Additionally, the generator is equipped with advanced soundproofing technology, reducing operational noise levels and making it suitable for use in noise-sensitive environments.

The MQD2H is designed with user convenience in mind. It features an intuitive control panel that provides easy access to vital operational information, allowing users to monitor the generator's performance at a glance. The control panel includes circuit breakers, start/stop switches, and hour meters, ensuring that operators have full control over the generator’s functionality.

Safety is also a priority with the Multiquip MQD2H. The generator incorporates automatic shutdown features for low oil pressure and high engine temperature, protecting the unit from potential damage. This built-in safety mechanism provides peace of mind for operators, knowing that the generator is safeguarded against operational hazards.

Furthermore, the MQD2H complies with emission regulations, making it an environmentally friendly choice among generators. The design includes technologies that minimize harmful emissions without compromising power output, adhering to industry standards and promoting cleaner operation.

In conclusion, the Multiquip MQD2H is a reliable, durable, and efficient generator ideal for a multitude of applications. With its powerful diesel engine, user-friendly controls, enhanced safety features, and commitment to environmental sustainability, it stands out as a top choice for professionals seeking dependable power solutions in demanding conditions.