maintenance
Check the battery regularly and make sure that each electrolyte level is to the bottom of the vent well (Figure 35). If necessary add only distilled water in a
Figure 35. Battery Electrolyte Levels
BATTERY CHARGING
DO NOT charge battery with the battery cables connected to the compactor. The diodes will be damage by the high voltage.
Batteries generate hydrogen gas which
can be highly explosive. DO NOT smoke or allow flames or sparks near the battery, especially during charging of the battery.
Charge the battery in a open air environment (plenty of ventilation).
Before charging , remove the cap from each cell of the battery.
Connect the positive (+) lead of the charger to the positive (+) terminal of the battery and the negative
Battery fluid will be lost through continuous charging and discharging.
Discontinue charging if the electrolyte temperature exceeds 117° F (45° C).
NOTICE
During summer much more battery fluid is lost than in winter. Before starting, check battery electrolyte levels and replenish with distilled water to the upper mark on the battery.
BATTERY CABLE CONNECTION (Option)
1.Take off the battery cover by removing the M6 nuts that secure the battery holder to the cover.
2.When removing battery cables, disconnect the ground side (normally negative) first (Figure 36).
3.When installing battery cable connect the ground side (normally negative) last.
+ TERMINAL
BATTERY COVER
- TERMINAL
BATTERY
Figure 36. Removing Battery Cover
mvh406dsz/dsCPAs pLATE COMPACTOR • operation and parts manual — rev. #7 (02/28/14) — page 27