Multiquip cx400, px400 manual Operation, Hose Connections, Attaching Lifting Rope

Models: px400 cx400

1 34
Download 34 pages 2.1 Kb
Page 17
Image 17

operation

Hose Connections

1.Connect a 2-inch hose to the discharge port on the pump as shown in Figure 11. Make sure that hose is attached correctly to the discharge port.

Attaching Lifting Rope

1.Attach a suitable lifting cable (rope) to the carrying handle (Figure 11) on the pump and lower the pump into place. For applications where there is an excessive amount of mud, grit or silt, the use of a support platform is desirable.When pumping water from swimming pool type applications where there is little or no debris, the support platform is not required.

 

 

EXTER

 

115 VAC

1Ø 115 VA

 

POWER S

 

POWER

 

 

 

PLUG

CIR

2-INCH

BRE

 

 

 

DISCHARGE

 

BLACK

 

 

HOSE

 

WHITE

 

 

GREEN

 

 

GND. B

 

POWER

 

LIFTING

CORD

 

ROPE

 

 

CARRYING

HANDLE

SUBMERSIBLE

SUBMERSIBLE

PUMP

Figure 12. Submersible Pump

Tilted Position (Incorrect)

Pump Power Connections (No Control Box)

1.

Make sure circuit breaker supplying power to pump

 

motor is in the OFF position.

2.

Insert the power cable plug (Figure 11) into the

 

appropriate power source receptable. The correct

 

source voltage for this pump is 115 VAC, 60 Hz,

 

single-phase.

SUPPORT

PUMP

3. If all of the pump's electrical requirements have been

PLATFORM

Figure 11. Submersible Pump

Upright Position (Correct)

2.Make sure the pump is always placed in an upright position (Figure 11, and not tilted (Figure 12). Never position the pump directly on a soft, loose bottom. Remember to attain maximum pumping capacity and prevent excessive wear. Position the pump so it will not burrow itself into sand or clay.

 

met, place the circuit breaker or power ON/OFF switch

 

in the ON position.

4.

Wait a few seconds and water should begin to flow

 

from the discharge hose.

5.

If water is not flowing from the discharge hose or not

 

flowing freely after a few minutes, place the circuit

 

breaker or ON/OFF switch in the OFF position and

 

check the system for leaks.

NOTICE

When connecting the pump directly to a power source (no control box), it is recommeded that personnel monitor the pump while in operation. Severe pump damge can occur if left unattended.

For unattended operation Multiquip recommends the use of the CB3 control box.

cx400/px400 Sub. pump • operation and parts manual — rev. #1 (12/03/10) — page 17

Page 17
Image 17
Multiquip cx400, px400 manual Operation, Hose Connections, Attaching Lifting Rope, Pump Power Connections No Control Box