ST-2005 SERIES SUB. PUMP GENERAL INFORMATION

Introduction

The Multiquip Model ST-2005 series submersible pumps are designed to pump water and is used for the draining (de- watering) of swimming pools, well casings construction sites, cofferdams, manholes, transformer vaults and excavations.

A cast iron ductile type impeller is attached to the output shaft of a 0.5 HP electric motor which provides adequate power for general purpose pumping. This submersible pump is supplied complete with an electric power cable, and a discharge port located at the top of the pump which accepts a 2-inch hose.

This pump is ideal for portability because of its light weight and carrying handle. For reliability and long life, a mechanical seal provides shaft sealing, with an oil chamber separating the pump section from the motor.

The pump when in use, should be installed as free standing (upright position) on its strainer base. A 2-inch discharge hose (not supplied) should be connected to the discharge port located on top of the pump.The discharge hose should be adequately supported to avoid stress on the pump.

For maximum water flow, the discharge hose should be kept as short as possible, and with minimum elevation above the pump. Remember as the length and/or height of the discharge hose is increased, the flow of water will be reduced. Also any reduction in the hose size, and any fittings such as valves or outlet nozzles, will restrict the water flow.

To avoid back-siphonage when the pump is switched off, ensure that the end of the discharge hose is installed above the water level at the final discharge point.

When the pump is switched off, the water remaining in the hose will run back through the pump.This can be avoided by placing a non-return valve in the hose nearest the pump.

NEVER use this submersible pump to pump flammable liquids or operate in a explosive or flammable environment.

Avoid using this pump in conditions where mud, grit, silt or other debris are present.These conditions could cause blockage and cause excessive pump wear.

DO NOT install the pump directly into an area where there is a heavy build-up of mud, grit, silt or debris. If this condition is present, install the pump on a platform before operating.

This pump must always be positioned on a platform in an upright position. NEVER operate the pump by a suspended rope. To prevent large solids from entering the pump, install a wire mesh screen or similar barrier around the pump.

If the pump was used to pump water containing mud, silt, use clean water to flush out the pump after each use.

DO NOT allow the pump to run dry, as this will damage the pump. During maintenance, dry running is permissible but only for a few seconds.

NEVER lift the pump by its electrical power cord. ALWAYS lift the pump by its carrying handle or attach a rope to the carrying handle.

A pump fully submerged pump in liquid will not freeze, unless the liquid freezes. DO NOT allow a partially submerged pump to freeze.The expansion of water freezing in the volute may crack the pump, causing expensive repairs. If there is any danger of the pump being subjected to freezing temperatures, Lift the pump from water and allow it to drain thoroughly.

If the pump jams or the pump rotor locks for any reason, disconnect the pump from the power source immediately. Allowing the pump motor to cycle ON and OFF under an overload condition can burn out the motor.

When replacement of nuts and bolts is required, use only recommended parts as referenced in the parts section of this manual.This pump uses metric threads. DO NOT use english measurement threads.

Control Box Installation Warnings

DANGER

When installing the CB3 control box, the possibility exists of electrical shock, electrocution and possibly death! NEVER have untrained personnel perform the installation. ALWAYS have qualified service personnel (licensed electrician) perform the installation.

WARNING

Explosion or Fire Hazard exists if this pump is used with flammable liquids. DO NOT use this pump with flammable liquids. DO NOT install this pump in

hazardous locations as defined by the National Electrical Code, ANSI/NFPA 70.

Failure to follow the above referenced precautions could result in serious injury or death! Replace pump cord immediately if cord becomes damaged or severed.This pump must be installed in accordance with National Electric Code ANSI/NFPA 70 so as to prevent moisture from entering or accumulating with the boxes, conduit bodies fittings, float housing or cable.

PAGE 10 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)

Page 10
Image 10
Multiquip ST-2005 manual Introduction, Control Box Installation Warnings

ST-2005 specifications

The Multiquip ST-2005 is a compact yet powerful generator that stands out in the market for its reliability and efficiency, making it a popular choice for construction sites, outdoor events, and emergency power needs. Engineered to deliver dependable electricity, it is equipped with advanced features and technologies that cater to both professional and personal use.

One of the standout features of the ST-2005 is its robust 4-stroke engine, which provides an impressive output of 2000 watts. This engine is designed with fuel efficiency in mind, allowing users to run their electrical tools and devices for extended periods without frequent refueling. The generator’s fuel tank has a capacity of 1.8 gallons, providing an operating time of up to 10 hours on a quarter load, a significant advantage for users requiring consistent power throughout the day.

Portability is another key characteristic of the Multiquip ST-2005. Weighing in at just around 50 pounds, this generator features a compact design that includes a sturdy frame and integrated wheels, allowing for easy transportation to various job sites or events. The foldable handle adds to its portability, making it convenient to store when not in use.

The ST-2005 incorporates state-of-the-art technologies that enhance its performance and usability. This includes an integrated inverter system that ensures clean and stable power output, making it suitable for sensitive electronic devices such as laptops and smartphones. Along with this, the generator features a low oil shutdown mechanism, which automatically turns off the engine if the oil level drops below a safe threshold, thereby protecting the engine from damage.

User-friendly control panels are another hallmark of the Multiquip ST-2005. The generator comes equipped with multiple output outlets, including 120V and 12V options, allowing users to connect a variety of devices simultaneously. Additionally, an easy-to-read watt meter provides real-time information on power usage, ensuring that users can efficiently manage their energy consumption.

In conclusion, the Multiquip ST-2005 is designed for durability, performance, and ease of use. With its powerful engine, portability, advanced inverter technology, and user-friendly features, it serves as an invaluable tool for anyone needing reliable power on the go, making it a worthy investment for both professionals and home users alike.