Nady Systems PM-200A owner manual Specifications, Panel Controls and connections

Models: PM-200A

1 8
Download 8 pages 23.92 Kb
Page 6
Image 6
SPECIFICATIONS

Panel Controls and connections

10. FUSE COMPARTMENT

Replace with only the same type fuse. If the fuse blows continuously, have the unit serviced by qualified personnel. The PM-200A powered mixer uses 20mm glass tube Fast Blow fuses: 6A 250V for 115VAC, 3A 250V for 230VAC.

11. AC VOLTAGE SELECTOR SWITCH

Before plugging in the power cord, check to see that the unit is set for the proper voltage for your area: ~115V (60Hz) or ~230V (50Hz).

12. HEAT SINK

The heat sink can get very hot during high power operation. Make sure to leave properly ventilated and avoid touching.

13. MOUNTING SOCKET

 

 

 

 

On the bottom panel of the PM-200A

 

 

 

 

is a 5/8” dia. socket for mounting the

 

 

13

 

PM-200A on a mic stand. Depending

 

 

 

on your mic stand, you may require

 

 

 

 

the optional MSA-100/200A Mic Stand

 

 

 

 

Adapter for most secure mounting. For

 

 

 

 

ordering, see PM-100/200A Optional

PM-200A bottom and

MSA-100/200A Mic

Accessories Ordering Form included.

standard mounting socket

Stand Adapter

SPECIFICATIONS

Mic Input

 

balanced XLR

Input Impedance

2KΩ

Maximum Input

-10.2dBm (235mV)

Sensitivity (for max output

w/Volume max)

-40dBm (7.5mV)

Line Input

balanced/unbalanced TRS 1⁄4”

Input Impedance

20KΩ

Maximum Input

(10KΩ unbalanced)

+22dBm (10V)

Sensitivity (for max output

w/Volume max)

-10dBm (230mV)

Line Output

 

balanced XLR

Output Impedance

1.4KΩ

Maximum Output

15.5dBm (4.3V)

(w/10K load)

 

EQ and Volume

rotary knobs

High

 

+/-12dB @ 10K Hz

Mid

 

+/-12dB @ 2.5K Hz

Bass

 

+/-12dB @ 120 Hz

Headphone Output

1⁄4” TRS Stereo

Power

 

2 x 80mW @ 32Ω

Power Amp Output

2 internal speakers,

Power

 

2 external 1⁄4” outputs

 

2 x 50W RMS @ 8Ω

 

 

(Total 100W RMS)

 

 

2 x 75W RMS @ 4Ω

 

 

(Total 150W RMS)

Frequency Response

20Hz – 50KHz

THD

0.055%

S/N

-81dB

Noise Floor

.200uV

Amplifier protection

clipping LEDs,

thermal runaway, short circuit,

anti-thump on/off protection

Internal Speakers

5” full-range

Impedance

8 Ω

Voice Coil diameter

1”

Power Requirements

Selectable,

115VAC/60Hz or 230VAC/50Hz

Fuse Requirements

5x20mm glass tube F.B.

 

6A 250V @ 115VAC

 

3A 250V @ 230VAC

Weight

9.6 lbs. (4.4 Kg)

Dimensions (HWD)

11.1” x 7” x 6.1”

 

(28 x 18 x 15.5 cm)

Specifications subject to change at any time without prior notice for purposes of product improvement

6

Page 6
Image 6
Nady Systems PM-200A owner manual Specifications, Panel Controls and connections