FUNCTION MENU
The keypad can provide access to a wide assortment of utility functions. The functions are displayed in a prompting “YES/NO” format.
1.To enter the Function Menu, press R.
•In all
2.To skip a function, answer NO (Q) or R.
3.To select and execute a function, answer YES (P) or U.
•Functions may be manually scrolled forward or backward using Rand B, respectively.
•To return to normal keypad operation, press the Cbutton. The keypad will automatically return to its normal operating mode if no activity is detected for longer than one minute.
01 INTERIOR BYPASS | FIRE/TBL | SYS TBL | CHIME | |
|
|
|
|
|
02 INTERIOR | BYPASS | FIRE/TBL | SYS TBL | CHIME |
|
|
|
|
|
03 INTERIOR | BYPASS | FIRE/TBL | SYS TBL | CHIME |
1.Display Zone Status? Displays the zone number of zones that are not secured. Press the NEXT and PRIOR Buttons (as displayed
2.Display Zones Bypassed? Displays bypassed zones. Press NEXT(P) and PRIOR (Q) to scroll bypassed zones.
3.Activate Bell Test? Activates the alarm (while disarmed) for about 2 seconds and performs a battery test. If the alarm does not sound, call for service. If the battery is low, a system trouble E02 will appear in the display. Allow 24 hours for the battery to recharge. If the trouble continues, call for service.
15