GAS KNOB

27

OPERATION / MAINTENANCE

When lit for the fi rst time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to suffi ciently ventilate the room.

After extended periods of non-operation such as following a vacation or a warm weather season, the fi replace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off.

Purge the gas line with a glass door open. Assure that a continuous gas flow is at the burner before re-install- ing the door.

FOR YOUR SAFETY READ BEFORE LIGHTING:

A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor.

C. Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a qualifi ed service technician. Force or at- tempted repair may result in a fi re or explosion.

D. Do not use this fireplace if any part has been under water. Immediately call a qualifi ed service technician to inspect the fi replace and replace any part of the control system and any gas control which has been under water.

WHAT TO DO IF YOU SMELL GAS:

Turn off all gas to the fi replace.

Open windows.

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbour's phone. Follow the gas sup- plier's instructions.

If you cannot reach your gas supplier, call the fi re depart- ment.

LIGHTING INSTRUCTIONS

WARNING: The gas valve has an interlock device which

5. Turn gas knob counter-clockwise to pilot.

will not allow the pilot burner to be lit until the thermocouple

6. Depress slightly and hold gas knob while lighting the pilot

has cooled. Allow approximately 60 seconds for the ther-

with the push button igniter. Keep knob depressed for one

mocouple to cool.

minute, then release. If pilot does not continue to burn,

When lighting and re-lighting, the gas knob cannot be turned

repeat steps 3 through 5.

from pilot to off unless the knob is depressed slightly.

7. With pilot lit, depress and turn gas knob counter-clock-

1.

Stop! Read the above safety information on this label.

wise to on.

2.

Turn off all electric power to the fi replace.

8. If equipped with remote on-off switch/thermostat, main

3.

Turn the gas knob clockwise to off.

burner may not come on when you turn valve to on. Remote

4.

Wait five (5) minutes to clear out any gas. If you smell

switch must be in the on position to ignite burner.

 

gas including near the floor. Stop! Follow "B" in the above

9. Turn on all electric power to the fi replace.

 

safety information on this label. If you don't smell gas go

 

 

the next step.

 

TO TURN OFF GAS

1.Turn off all electric power to the fi replace if service is to be performed.

2.For a complete shut-down procedure: push in gas control knob slightly and turn clockwise to off. Do not force.

3.For a temporary shut-down procedure: set thermostat to lowest setting or remote switch to off. Press and turn the gas knob clockwise to pilot.

MAINTENANCE

Turn off the gas and electrical power before servicing the

fireplace.

CAUTION: Label all wires prior to disconnection when servic- ing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. This fireplace and its venting system should be inspected before use and at least annually by a qualifi ed service person. The fi replace area must be kept clear and free of combustible materials, gasoline or other fl ammable vapours and liquids. The fl ow of combustion and ventilation air must not be obstructed.

1.In order to properly clean the burner and pilot assembly, remove the logs to expose both assemblies.

2.Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacuum- ing or brushing, at least once a year.

3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly.

4.Check to see that the pilot fl ame is large enough to engulf the thermocouple and thermopile and reaches toward the burner with the third jet.

5.Replace the cleaned logs.

6.Check to see that the main and runner burners ignite completely on all openings when the gas knob for the burn- ers is turned on. A 5 to 10 second total light-up period is satisfactory. If ignition takes longer, consult your Authorized dealer / distributor.

7.Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if necessary.

W415-0299 / J / 04.14.08

Page 27
Image 27
Napoleon Fireplaces BGD40-P, BGD40-N manual Operation / Maintenance, Fireplace

BGD40-P, BGD40-N specifications

Napoleon Fireplaces has long been a name synonymous with quality and innovation in the realm of hearth products. Among its impressive lineup, the BGD40-N and BGD40-P models stand out for their blend of performance, aesthetics, and technology, making them ideal choices for homeowners seeking both efficiency and style.

The BGD40-N is a natural gas fireplace, designed with an emphasis on creating a warm and inviting atmosphere. One of its main features is the glass front that enhances its visual appeal while providing a clear view of the mesmerizing flames. This model is equipped with Napoleon's patented PHAZER log set, which mimics the appearance of real wood, further enriching the realistic ambiance.

In contrast, the BGD40-P is a propane version of the fireplace, offering similar design aesthetics and functionality tailored to propane users. Both models boast a high-efficiency rating, which means they maximize heat output while minimizing gas consumption. This efficiency not only reduces energy costs but also makes them environmentally friendly options for home heating.

One of the standout technologies featured in the BGD40 series is the advanced electronic ignition system. This system ensures that igniting the fireplace is a hassle-free experience, even during power outages when using the optional battery backup. Furthermore, the exclusive Heat Management System provides optimal airflow and distribution of heat, ensuring that living spaces are warmed effectively and consistently.

Safety features are paramount in both models, with a built-in safety shut-off system that enhances peace of mind for users. Additionally, the adjustable flame height allows homeowners to customize their experience, ranging from a gentle glow to a roaring fire.

The design flexibility of the BGD40-N and BGD40-P allows them to fit seamlessly into various home décors, complementing both modern and traditional interiors. With their sleek lines and customizable options, including different media choices, these fireplaces serve as focal points in any room.

Installation is straightforward, with options available for both vented and direct vent configurations. This versatility means they can be installed in various locations, making them suited for new builds or retrofitting into existing structures.

In summary, Napoleon Fireplaces' BGD40-N and BGD40-P models deliver on aesthetics, efficiency, and innovative technology. With their realistic flame effects, user-friendly features, and commitment to safety, they are excellent choices for those seeking to enhance the comfort and ambiance of their homes.