Napoleon Fireplaces BGD48P, BGD48N manual V1, H2, Horizontal Termination

Models: BGD48N BGD48P

1 28
Download 28 pages 15.49 Kb
Page 11
Image 11
V1

HORIZONTAL TERMINATION

11

when (HT) > (VT)

Simple venting confi guration (only one 45º and 90° elbow)

See graph to determine the required

vertical rise VT for the required hori- FIGURE 8 zontal run HT.

Example 2:

FIGURE 9

 

90° 90°

 

90°

H1

H3

V

 

 

 

 

 

2

H4

V1

45°

H2

90°

REQUIRED

VERTICAL

RISE IN

INCHES (VT)

HORIZONTAL VENT RUN PLUS OFFSETS IN FEET

The shaded area within the lines represents acceptable values for HT and VT .

For vent confi gurations requiring more than one 45º and 90° elbow the following formulas apply:

Formula 1: HT < 4.2 VT

Formula 2: HT + VT < 24.75 feet

V1

= 4 ft

V2

= 1.5 ft

VT

= V1 + V2 = 4 ft + 1.5 ft = 5.5 ft

H1

= 2 ft

H2

= 1 ft

H3

= 1 ft

H4

= 1.5 ft

HR

= H1 + H2 + H3 + H4 = 2 + 1 + 1 + 1. 5 = 5.5 ft

HO

= .03 (one 45º elbow + four 90º elbows -135º)

 

=.03 (405-135)=8.1ft

HT

= HR + HO = 5.5 + 8.1 = 13.6ft

HT + VT

= 13.6 + 5.5 = 19.1 ft

Formula 1: HT < 4.2 VT

4.2VT = 4.2 x 5.5 = 23.1 ft

13.6< 23.1

Formula 2: HT + VT < 24.75 feet

19.1 < 24.75

Since both formulas are met, this vent confi guration is ac- ceptable.

W415-0326 / C / 11.23.07

Page 11
Image 11
Napoleon Fireplaces BGD48P, BGD48N manual V1, H2, Horizontal Termination