22

OPERATION / MAINTENANCE

OPERATING INSTRUCTIONS

When lit for the fi rst time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again.

After extended periods of non-operation such as following a vacation or a warm weather season, the fi replace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. In both cases, open a window to suffi ciently ventilate the room.

Purge the gas line with the glass door removed. Assure that a continuous gas flow is at the burner before reinstalling the door.

FOR YOUR SAFETY READ BEFORE LIGHTING:

A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B. Before operating smell all around the fi replace area for gas and next to the floor because some gas is heavier than air and will settle on the fl oor

C. Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a quali-

fi ed service technician. Force or attempted repair may result in a fi re or explosion.

D.Do not use this fi replace if any part has been under water. Imme- diately call a qualifi ed service technician to inspect the fi replace and replace any part of the control system and any gas control which has been under water.

WHAT TO DO IF YOU SMELL GAS

• Turn off all gas to the fi replace.

• Open windows.

FIGURE 53

 

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neigh- GAS KNOB bour's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fi re department.

FIGURE 54

LIGHTING INSTRUCTIONS

WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermocouple has cooled. Allow approximately 60 seconds for the thermocouple to cool.

When lighting and relighting, the gas knob cannot be turned from pilot to off unless the knob is depressed slightly.

1.Stop! Read the above safety information on this label.

2.Turn off all electric power to the fi replace.

3.Turn the gas knob clockwise to off.

4.Wait five (5) minutes to clear out any gas. If you smell gas includ- ing near the fl oor. Stop! Follow "B" in the above safety information on this label. If you don't smell gas go the next step.

5. Turn gas knob counter-clockwise to pilot.

6.Depress slightly and hold gas knob while lighting the pilot with the push button igniter. Keep knob depressed for one minute, then release. If pilot does not continue to burn, repeat steps 3 through

7.With pilot lit, depress and turn gas knob counter-clockwise to

on.

8.If equipped with remote on-off switch/thermostat, main burner may not come on when you turn valve to on. Remote switch must be in the on position to ignite burner.

9.Turn on all electric power to the fi replace.

TO TURN OFF GAS

1.Turn off all electric power to the fi replace if service is to be 2. Push in gas control knob slightly and turn clockwise to off. Do

performed.

not force.

MAINTENANCE

 

3.

Check to see that all burner ports are burning. Clean out any of

Turn off the gas and electrical power before servicing the

the ports which may not be burning or are not burning properly.

fireplace.

4.

Check to see that the pilot fl ame is large enough to engulf the

CAUTION: Label all wires prior to disconnection when servicing

thermocouple and thermopile and reaches toward the burner with

controls. Wiring errors can cause improper and dangerous operation.

the third jet.

Verify proper operation after servicing. This fi replace and its venting

5.

Replace the cleaned logs.

system should be inspected before use and at least annually by a

6.

Check to see that the main burner ignites completely on all open-

qualifi ed service person. The fi replace area must be kept clear and

ings when the gas knob for the burner is turned on. A 5 to 10 second

free of combustible materials, gasoline or other fl ammable vapours

total light-up period is satisfactory. If ignition takes longer, consult

and liquids. The fl ow of combustion and ventilation air must not be

your Napoleon® dealer / distributor.

obstructed.

7.

Check that the gasketing on the sides, top and bottom of the door

is not broken or missing. Replace if necessary.

1. In order to properly clean the burner and pilot assembly, remove the logs to expose both assemblies.

2. Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year.

W415-0326 / C / 11.23.07

Page 22
Image 22
Napoleon Fireplaces BGD48N, BGD48P manual Operation / Maintenance, Operating Instructions, Open windows, Fireplace

BGD48N, BGD48P specifications

Napoleon Fireplaces has long been a name synonymous with quality and innovation, and their BGD48N and BGD48P models are prime examples of their commitment to excellence. These fireplaces serve as a beautiful focal point in any home while providing efficient heating solutions.

The BGD48N features a classic design that echoes the elegance of traditional fireplaces. With its wide viewing area, it delivers an impressive display of flames, creating a warm and inviting atmosphere. The BGD48P, on the other hand, offers a more contemporary aesthetic, featuring clean lines and a sleek facade that complements modern decor. Both models are built with high-quality materials and craftsmanship, ensuring durability and longevity.

One of the key technologies integrated into these fireplaces is the advanced heat management system, which efficiently distributes warmth throughout the room without overheating the unit. This system uses a combination of convection and radiant heat, ensuring that the space is evenly warmed while maximizing fuel efficiency. The incorporation of a ceramic glass front allows for optimal heat retention and provides an unobstructed view of the flickering flames.

The BGD48N and BGD48P are powered by Napoleon's innovative firebox technology, which permits a variety of fuel options, including natural gas and propane. This flexibility allows homeowners to choose the heating source that best fits their needs and preferences. Additionally, these models are equipped with a powerful fan system that enhances heat circulation, thereby increasing overall efficiency.

Safety and convenience are paramount in the design of these fireplaces. Each model comes with a straightforward control panel, allowing users to easily adjust the temperature and flame height. An automatic shut-off feature ensures peace of mind, providing an added layer of safety for families. The inclusion of easy-access maintenance features also makes cleaning and upkeep a breeze.

With their combination of classic styling, modern technology, and user-friendly features, Napoleon Fireplaces BGD48N and BGD48P models stand out in the market. They offer a sophisticated heating solution that not only enhances ambiance but also improves energy efficiency. Whether you are seeking a traditional touch or a modern aesthetic, these fireplaces cater to diverse tastes, making them an excellent investment for any homeowner looking to elevate their living space.