Napoleon Fireplaces fireplaces manual Glowing Embers, Charcoal Embers, Hood Curtain Mesh

Models: fireplaces

1 24
Download 24 pages 12.88 Kb
Page 14
Image 14
GLOWING EMBERS

14

GLOWING EMBERS

Tear the embers into small pieces and place on the ported area of the burner. Care should be taken to shred the embers into thin, small irregular pieces as only the ex- posed edges of the fibre hairs will glow. The ember mate- rial will only glow when exposed to direct flame; however, care should be taken to not block the burner ports. Blocked burner ports can cause an incorrect flame pattern, carbon deposits and delayed ignition. PHAZERTM logs glow when

Dashed lines are suitable mantle sizes and clear- ances when a non-combus- tible facing is used.

FIGURE 25

HOOD

exposed to direct flame.

CHARCOAL EMBERS

Randomly place the embers around the bottom brick pan- els in a realistic manner but not in contact with the flames. Keep ember dust away from burner ports to avoid plugging them.

Fine dust found in bottom of bag not to be used. PHAZERTM logs, and embers glow when exposed to direct flame. Use only certified PHAZERTM logs, glowing embers and char- coal embers available from your Napoleon / Wolf Steel Ltd. dealer.

HOOD

CURTAIN

MESH

FIGURE 26

GLOWING EMBERS

The curtain mesh must be kept fully closed during opera- tion to help prevent accidental burns from occurring.

22

CURTAIN SUPPORT

PLATE

HOOD

FIGURE 27

The heater must not be used when the hood is re- moved. Hook the hood over the lip of the curtain support plate.

Ensure that glowing embers sufficiently cover the carry over ports, highlighted below, to achieve maximum glow.

CARRY OVER PORTS

FIGURE 23

MANTLE INSTALLATION

Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clear- ance needed. The four-sided top extension piece may be removed if non-combustible framing is faced with a non- combustible material.

FIGURE 24

UPPER LOUVRE BRACKETS & HOOD

FIGURE 28

Attach the hood with louvre brackets by pressing the top flange of the bracket into the clips along the top of the louvre opening with louvre securing tabs facing out.

NOTE: The protective wrap is best removed when the assembly is at room temperature but this can be improved if the assembly is warmed, using a hair dryer or similar heat source.