13

USING FLEXIBLE VENT COMPONENTS

Use only approved aluminum flexible liner kits marked:

"Wolf Steel Approved Venting" as identified by the stamp only on the 8” outer liner.

HORIZONTAL AIR TERMINAL INSTALLATION

1.Cut or frame a hole in an exterior wall with a minimum round or square opening of 121/2" W x 121/2" H. Secure the firestop spacer over the opening to the interior wall.

Secure the terminal to the terminal extension plate (see fig- ure 19).

2.Stretch the 5" diameter aluminum flexible liner to the required length taking into account the additional length needed for the finished wall surface. Slip the liner a mini- mum of 2" over the inner sleeve of the air terminal and se- cure with 3 #8 screws. Apply a heavy bead of the high tem- perature sealant (W573-0007 not provided).

3.Using the 8" diameter flexible aluminum liner, slide over the outer combustion air sleeve of the air terminal and se- cure with 3 #8 screws. Seal as before.

FIGURE 17

For safe and proper operation of the fireplace, follow the venting instructions exactly.

All inner exhaust and outer intake vent pipe joists may be sealed using either Red RTV high temp silicone seal- ant or Black high temp Mill Pac with the exception of the fireplace exhaust flue collar which must be sealed using Mill Pac (not supplied).

4.Insert the liners through the firestop maintaining the required clearance to combustibles. Secure to the exterior wall and make weather tight by sealing with caulking (not supplied).

5.Apply a heavy bead of the high temperature sealant, not supplied with the unit, to the inside of the 5" liner approxi- mately 1" from the end. Slip the liner a minimum of 2" over the fireplace vent collar and secure with 3 #8 screws.

6.Using the 8" diameter flexible aluminium liner, apply seal- ant, slide a minimum of 2" over the fireplace combustion air collar and secure with 3 #8 screws.

VERTICAL AIR TERMINAL INSTALLATION

1. Fasten the roof support to the

FIGURE 19

roof using the screws provided.

 

The roof support is optional.

 

In this case the venting is to

 

be adequately supported

 

using either an alternate

 

method suitable to the au-

 

thority having jurisdiction

 

or the optional roof sup-

 

port.

 

2.Stretch the 5" diameter aluminium flexible liner to the required length. Slip the liner a minimum of 2" over the inner sleeve of the air terminal and secure with 3 #8 screws. Seal using a heavy bead of the high temperature sealant (W573- 0007 not supplied).

3.Repeat using 8" diameter aluminium flexible liner.

4.Thread the air terminal pipe

 

assembly down through the

FIGURE 20

 

roof. The air terminal must be

 

 

located vertically and plumb. At-

 

 

tach the air terminal assembly

 

FIGURE 18

to the roof support, ensuring that

 

a minimum 16" of air terminal

 

 

 

 

will penetrate the roof when fas-

 

 

tened.

 

DO NOT CLAMP THE FLEX-

IBLE ALUMINIUM LINER.

W415-0447 / B / 05.24.05

Page 13
Image 13
Napoleon Fireplaces GD80NT, GD80PT manual Using Flexible Vent Components, Horizontal AIR Terminal Installation